1. MAX / MIN / Data Hold.
2.Phase Rotation Indicator.
3. 1000A AC & 600V AC.
4.Pos Peak Hold & Neg Peak Hold.
Port: Shenzhen or Guangzhou
Minimum Order Quantity: 10 Set/Sets
Supply Ability: 10000 Set/Sets per Month
Payment Terms: T/T,Western Union
Contact SupplierPackaging Detail: 1 set / box
Delivery Detail: 3-5days
Feature
.Capacitance Measurement (400uF).
•MAX / MIN / Data Hold.
•Phase Rotation Indicator.
•Pos Peak Hold & Neg Peak Hold.
•1000A AC & 600V AC.
Specification
A, General Measurement
AC Current
Range | Resolution | Accuracy | Frequency Response | Overload Protection |
40A | 0.01A | ±(2% + 5) | 40 ~ 400Hz | 1100A |
400A | 0.1A | |||
1000A | 1A |
AC Voltage
Range | Resolution | Accuracy | Input Impedance | Frequency Response | Overload Protection |
400V | 0.1V | ±(1.2%+5) | 1MΩ | 40 ~ 400Hz | 600Vrms |
600V | 1V | ±(3%+5) |
B, Peak Hold Measurement
AC Current
Range | Resolution | Accuracy | Overload Protection |
40A | 0.01A | Cables 40mm(2.5% + 10) | 1100A |
400A | 0.1A | ||
1000A | 1A |
GENERAL SPECIFICATIONS
Numerical Display | 3-3/4 digit liquid crystal display (LCD) maximum reading 3999 42 segment bargraph. |
Range Selection | All ranges are selected by a single range switch. |
Over Range Indication | LCD will show an "OL". |
Low Battery Indication | LCD will show an |
Sampling Rate | 2 times/sec (Digits) 10 times/sec (Analog). |
Power Source | one 006p 9V or IEC 6F22 or NEDA 1604 Battery. |
Battery Life | 200hr approx. |
Polarity | Automatic polarity " - " display for negative input. |
Operating & storage / Temperature and Humidity | 0°C to 40°C(32°F to 104°F) < 80%RH/-10°C to 60°C (14°F to 140°F) < 70% RH |
Dimensions and Weight | 228(L) ×76(W) ×39(H)mm and Approx. 465g |
Jaw Opening Diameter | Cables 40mm |