1.Range:0 to 30m
2.Process temp:-40C to +250C
3.Pressure:-0.1 to +2.0Mpa
Accurancy:+/-0.1%
Port: Dandong
Minimum Order Quantity: 1 Unit/Units none
Supply Ability: 200 Unit/Units per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: Package: Cardboard box (cm) 52 x 31 x 31Gross Weight: 5.5 Kg or may be subject to model selected.
Delivery Detail: within 15 days after receipt of full payment
TDR Guided Wave VRWKRD31
Advantages:
1. Simple setup without adjustment
2. Unaffected by product properties
3. Insensitive against dust, vapour, buildup and condensation
4. Wear and maintenance-free
5. High measuring accuracy
Function:
High frequency microwave pulses are coupled onto a cable or rod and guided along the probe. The pulses are reflected by the product surface. The time from emission to reception of the signals is proportional to the level in the vessel.
Guided Wave Radar Level Transmitter VRWKRD31:
Application: fluids, solid powders
Measuring range: 30m
Process connection: screw thread / flange
Process temperature:-40°C- +250°C
Pressure:-0.1 to +2.0Mpa
Process pressure:-0.1 to +2.0Mpa
Repeatability: ±2mm
Accuracy: +/-0.1%
Frequency range: 100MHZ-1.8GHZ
Explosion proof: Exia II C T6
Ingress protection: IP67
Signal output: 4…20mA/HART (two wires)
Power supply: 24V DC
Guided Wave Radar Level Transmitter VRWKRD32:
Application: fluids, solid powders
Measuring range: 6m
Process connection: screw thread / flange
Process temperature:-40°C- +250°C
Pressure:-0.1 to +2.0Mpa
Process pressure:-0.1 to +2.0Mpa
Repeatability: ±2mm
Accuracy: +/-0.1%
Frequency range: 100MHZ-1.8GHZ
Explosion proof: Exia II C T6
Ingress protection: IP67
Signal output: 4…20mA/HART (two wires)
Power supply: 24V DC
Guided Wave Radar Level Transmitter VRWKRD33:
Application: ideal for fluids with low dielectric constant, solid powders,
Measuring range: 6m
Process connection: screw thread / flange
Process temperature:-40°C- +250°C
Pressure:-0.1 to +2.0Mpa
Process pressure:-0.1 to +2.0Mpa
Repeatability:±2mm
Accuracy: +/-0.1%
Frequency range: 100MHZ-1.8GHZ
Explosion proof: Exia II C T6
Ingress protection: IP67
Signal output: 4…20mA/HART (two wires)
Power supply: 24V DC
Guided Wave Radar Level Transmitter VRWKRD34:
Application: ideal for fluids with low dielectric constant, solid powders
Measuring range: 6m
Process connection: screw thread / flange
Process temperature:-40°C- +250°C
Pressure:-0.1 to +2.0Mpa
Process pressure:-0.1 to +2.0Mpa
Repeatability: ±2mm
Accuracy: +/-0.1%
Frequency range: 100MHZ-1.8GHZ
Explosion proof: Exia II C T6
Ingress protection: IP67
Signal output: 4…20mA/HART (two wires)
Power supply: 24V DC
Guided Wave Radar Level Transmitter VRWKRD35:
Application: ideal for corrosive fluids
Measuring range: 6m (rod type) / 20m (cable type)
Process connection: screw thread / flange
Process temperature:-40°C- +250°C
Pressure:-0.1 to +2.0Mpa
Process pressure:-0.1 to +2.0Mpa
Repeatability: ±2mm
Accuracy: +/-0.1%
Frequency range: 100MHZ-1.8GHZ
Explosion proof: Exia II C T6
Ingress protection: IP67
Signal output: 4…20mA/HART (two wires)
Power supply: 24V DC
Guided Wave Radar Level Transmitter VRWKRD36:
Application: ideal fluids with low dielectric constant or fluctuation.
Measuring range: 6m
Process connection: screw thread / flange
Process temperature:-40°C- +250°C
Pressure:-0.1 to +2.0Mpa
Process pressure:-0.1 to +2.0Mpa
Repeatability: ±2mm
Accuracy: +/-0.1%
Frequency range: 100MHZ-1.8GHZ
Explosion proof: Exia II C T6
Ingress protection: IP67
Signal output: 4…20mA/HART (two wires)
Power supply: 24V DC
Guided Wave Radar Level Transmitter VRKTRD71:
Application: fluids, solid particles
Measuring range: 30m
Process connection: G1A and1NPT, and DN50, DN80, DN100, DN150
Process temperature:-40°C- +250°C, cooling fin (optional)
Pressure:-0.1 to +2.0Mpa
Process pressure:-0.1 to +2.0Mpa
Accuracy: +/- 1mm
Frequency range: 100MHZ-1.8GHZ
Explosion proof: Exia II C T6
Ingress protection: IP68
Signal output: 4…20mA/HART (two wires)
Guided Wave Radar Level Transmitter VRKTRD72:
Application: fluids, solid particles
Measuring range: 6m
Process connection: G1A and1NPT, and DN50, DN80, DN100, DN150
Process temperature:-40°C- +250°C, cooling fin (optional)
Pressure:-0.1 to +2.0Mpa
Process pressure:-0.1 to +2.0Mpa
Accuracy: +/- 1mm
Frequency range: 100MHZ-1.8GHZ
Explosion proof: Exia II C T6
Ingress protection: IP68
Signal output: 4…20mA/HART (two wires)
Guided Wave Radar Level Transmitter VRKTRD73:
Application: fluids, solid particles
Measuring range: 6m (double rod) / 30m (double cable)
Process connection: G1A and1NPT, and DN50, DN80, DN100, DN150
Process temperature:-40°C- +250°C, cooling fin (optional)
Pressure:-0.1 to +2.0Mpa
Process pressure:-0.1 to +2.0Mpa
Accuracy: +/- 1mm
Frequency range: 100MHZ-1.8GHZ
Explosion proof: Exia II C T6
Ingress protection: IP68
Signal output: 4…20mA/HART (two wires)