X-ray diffractometer
1,the vertical or horizontal goniometer.
2,the qualitative and quantitative analysis.
Port: any port in China
Minimum Order Quantity: 1 Set/Sets None
Supply Ability: 5 Set/Sets per Month None
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: woodenbox
Delivery Detail: 22 workingdays
X-ray diffractometer
Application fields
1,the qualitative phase of the sample or the quantitative analysis,
2,the crystal analysis,
3,the material structure macroscopic stress or the microscopic stress determination,
4,the grain size determination, crystallinity determination and so on.
TD series X-ray diffractometer technical parameters
Name | Items | TD-2500 | TD-3000 | TD-3500 | ||||
X-ray tube (domestic or import) | Type | Tube voltage 60kV(target arbitrary choice Cu.Fe.Co.Cr.Mo) | ||||||
Focus size | 1×10mm2 | 1×10mm2or 0.4×14mm2 | ||||||
Maximum output power | 2.0kW | 2.4 kW or 2.7 kW | ||||||
X-ray Generator | Control mode | Microcomputer automatic 1Kv/step 1mA/step | ||||||
Maximum output power | 5kW | |||||||
X-ray tube voltage | 10-60kV | |||||||
X-ray tube current | 5-80mA | 2-80mA | ||||||
Stability | <0.01% | |||||||
Alarm device | There are Kv too high,Kv too lower,mA too high,mA too lower,no water,X-ray tube over-temperature, machine over-current protection and X-ray tube power protection etc. | |||||||
Goniometer | structure | horizontal(θ-2θ) | vertical(θ-2θ) | Sample levelθs-θd | ||||
Goniometer scanning radius | 185mm(150~285mm adjustable) | |||||||
Scanning range | 0°~164°(2θ) | -35°~170° | -35°~170°(measuring range) | |||||
-180°~180°(θ) | -35°~85°(θs/θd linkage) -35°~170°(θs/θd single action) | |||||||
Scanning speed | 0.06°-76.2°/min | 0.006°-96°/min | ||||||
Scanning mode | θ-2θ linkage,θ, 2θ single action,continuous or step scanning | θs/θd linkage, single action | ||||||
Minimum step angle | 0.001° | 0.0001° | ||||||
Measuring accuracy | ≤0.005° | ≤0.001° | ||||||
Angle positioning speed | 120°/min | 1000°/min | ||||||
2θ repeatability accuracy | ≤0.001° | ≤0.0005° | ||||||
Recording/ Control Unit | counter | Proportional (PC) or scintillation(SC) | ||||||
Maximum linear count rate | 5×106CPS | 1×107CPS | ||||||
Spectrum resolution(Cu.kα spectrum linear) | ≤25%(PC)or≤60%(SC) | ≤20%(PC)or≤50%(SC) | ||||||
Counter high voltage | 0-2100V or 0-1100V continuously adjustable | |||||||
Counter mode | PLC automatic control differential integral mode conversion,automatic PHA,dead time correction | |||||||
Detector high voltage stability | Excel ±0.01% | Excel ±0.005% | ||||||
x-ray leakage | less than 0.1 μSv/h | |||||||
aggregative indicator | Safety indicators | Protection system for double protection, have a big and a small shield, to ensure the safety of the users | ||||||
Integrated stability | ≤0.5% | ≤0.3% | ||||||
Overall dimensions | 1100×920×1750mm |