Pressure Range:-1 Bar-0-1 Bar~50 Bar
Power Supply:9~36 V DC
Output: 4~20mA
Electronic Wire:2 Wires
Port: Shenzhen/Guangzhou
Minimum Order Quantity: 1.00 Piece/Pieces
Supply Ability: 5000 Piece/Pieces per Month
Payment Terms: T/T,Western Union
Contact SupplierPackaging Detail: Standard packages
Delivery Detail: 4-6weeks
Characters: Accuracy: ≤±0.5%F.S Wide working temperature scope Advanced digital temperature compensation Excellent resistance against impact, overload, shock and erosion Highly-efficient lighting absorption Strong RFI & EMI resistance 2 times range standard overload 3 times range burst pressure CE approved | Applications: Rivers water level and floodwater level monitor Medical testing system Well level measurement Saving water to irrigate Laboratory equipment Oil and fuel tank level measuring Automatic detection system Sea water level measurement Kinds of tank pressure and level measurement And so on |
Specifications:
Model: Parameter: | HPT603/HPT604/HPT612 | |||
Pressure Range: | -1 Bar-0-1 Bar.....50 Bar / 0-1M........500M H2O | |||
Overload: | 150% F.S. | |||
Accuracy: | ≤ ±0.5%F.S;≤ ±0.25%F.S;Optional | |||
Long Stability: | Standard: 0.1%F.S±0.05% | |||
Working Temp: | -30°C~80°C | |||
Storage Temp: | -40°C~120°C | |||
Temperature Compensation: | -20°C~75°C | |||
Medium compatible: | Compatible with 316L Stainless Steel | |||
Electronic Wire: | 2 Wires | 3 Wires | ||
Output: | 4~20mA | 0~5V | 0~10 V | 0.5~4.5 V |
Power Supply: | 9~36 V DC | 9~36 V DC | 15~36Vdc | 5 V DC |
Insulate resistance: | >100M Ω @100V | |||
Zero Temp. Drift: | 0.03%FS/°C(≤100kPa), 0.02%FS/°C(>100kPa) | |||
FS Temp. Drift: | 0.03%FS/°C(≤100kPa), 0.02%FS/°C(>100kPa) | |||
Electronic connection: | Sealed cable water proof IP68; Explore Proof Box IP65 (HPT612), But sensor IP68. | |||
Process Connect: | G1/2’’ G1’’, 1/2’’NPT, 1’’NPT, M20*1.5, M22*1.5, Flange or By Customized. | |||
Response time: | ≤ 4ms | |||
Pressure Type: | Gauge pressure, Absolute pressure optional. | |||
Certificate approving: | Exia IICT6 explores proof and CE Certificate. | |||
EMC Standard: | electromagnetic radiation:EN50081-1/-2; electromagnetic susceptibility:EN50082-2 | |||
Remarks: | Special applications request By Customized |
Dimension Drawings: