Home  >  Other Measuring & Analysing Instruments

Strain Gauge Torque transducers - 1915/1995

Strain Gauge Torque Transducers Model 1915/1995 - more info check here: http://www.buymeasuringtools.com/Strain-Gauge-Torque-transducers-10197546/

Quick Brief

Place of Origin: Belgium Brand Name: BCM SENSOR Model Number: 1915/1995 material: Material: alloy steel, stainless stee...

Product Features:

Strain Gauge Torque Transducers Model 1915/1995

Business Terms:

Port: Xi'an/China

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 300 Piece/Pieces per Month

Payment Terms: T/T

Contact Supplier
Strain Gauge Torque transducers
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: BCM standard inner box and exported carton with calibrated report together

Delivery Detail: In 25 days after receipt of your fornal order

Specifications and Product Details:

Description

Model 1915/1995 torque transducers are made from alloy steel (1915) or stainless steel (1995) and sealed to IP 66 protection grade for torque measurement applications.

Based on BCM advanced metal foil strain gauge technology, the sensing elements of these 19-series torque transducers are BCM strain gauges. These strain gauges form a Wheatstone bridge to sensing the deformation of the torque transducers, the deformation results from two torques which act around the axis on contrary directions. So the 1915/1995 torque transducer is operated the bottom the transducer is fixed as stationary part, while the top four square as motion part which intend to have torsion shift corresponding to the stationary part. Therefore these torque transducers are served as calibrating instrument of torque wrench, torsion measurement of shaft or concerned torque measurement.

BCM 1915/1995 torque transducers can be used to measure the torques ranging from 100 Lb.in ~ 5000 Lb.ft, and possess higher accuracy up to 0.2%fso. The output signal is Wheatstone bridge output voltage (mV/V) but can be amplified and configured to either 4~20mA current signal or 0.5~5V or 0.5~10V voltages on request. For connecting of both the output signal and electric excitation of the bridge, the electrical 4-pin connector is fixed at side of housing. The 1915/1995 torque transducer features a rigid and compact construction, small dimensions, easy to be installed or replaced in the installation position.

Features:

1. Capacity: 100 lb.in, …, 5000 lb.ft.

2. Accuracy: 0.2 ~ 0.3 %fso

3. Output: Wheatstone bridge circuit output (mV/V)

Amplified signals (e.g. 4~20 mA or 0.5~5 V) are available on request

4. Material: alloy steel (1911), stainless steel (1991)

5. Protection class: IP 65

6. Application: torque wrench and torsion, measurement of shaft

Specifications:

capacityI=Lb.in F=Lb.ft100I,250I,500I,750I, 50F,100F,250F,500F,1000F,2500F,5000F
rated outputm V/V2.0~±0.2
accuracy%FSO± 0.2~±0.3
zero unbalance%FSO±1.0
non-linearity%FSO± 0.2~±0.3
hysteresis%FSO± 0.2~±0.3
repeatability%FSO± 0.2~±0.3
temperature coefficient of ZERO%FSO / 10°C0.2~0.3
temperature coefficient of SPAN%FSO / 10°C0.2~0.3
input resistanceΩ400±30
output resistanceΩ350±10
insulation resistance≥1000@50 VDC
excitation recommendedV12 DC /AC
maximum excitationV15 DC /AC
compensated temperature range°C.-10~ + 40
operating temperature range°C.-20~ + 65
safe overload%FS120
ultimate overload%FS150
cable lengthm,shielded PVC cable1( 5mm 4 wire)

How to order: model-capacity-output-accuracy-IP rating-cable length-customer specific requests

Ordering code example: 1915-500F-2m V/V-0.2%fso-IP65-1m-no specific requests