Based on BCM strain gauge technology, model 166Z single point load cells are made of double bending beam working principle. Made from aluminum alloy, these load cells feature low profile and are widely used in applications such as postage scales, kitchen scales, portable scales and other platform scales.
Features :
1. type: single point (off center) load cell
2. material:aluminum alloy
3. surface:anodized treatment
4. protection:IP 65
5. application: postage scales, kitchen scales, personal scales, portable scales and other platform scales.
Specifications: | ||
capacity | kg | 100, 150 |
safe overload | %FS | 120 |
ultimate overload | %FS | 150 |
rated output | mV/V | 2.0 ± 0.1 |
excitation voltage | Vdc | 5 ~ 10 |
maximum excitation | V | 15 |
combined error | %FSO | ± 0.02 |
zero unbalance | %FSO | ± 2.0 |
non-linearity | %FSO | ± 0.02 |
hysteresis | %FSO | ± 0.02 |
repeatability | %FSO | ± 0.02 |
creep | %FSO/30min | ± 0.02 |
input resistance | Ω | 410 ± 10 |
output resistance | Ω | 350 ± 10 |
insulation resistance | M Ω | ≥ 2000 @ 50 Vdc |
operating temperature range | -20 ~ +60 | |
compensated temperature range | -10 ~ +50 | |
temperature coefficient of SPAN | %FSO/ | ± 0.002 |
temperature coefficient of ZERO | %FSO/ | ± 0.003 |
electrical interface | Cable | 4-core shielded PVC cable cable dia.: Φ4.0 mm; cable length: 450 mm |
How to order:model-capacity-output,bridge resistance-accuracy-cable specifications-customer specific requests (if any)
ordering code example: 166Z - 100kg - 2mV/V - 0.03%FSO - cable (Φ4.0mm, 4-core shielded PVC cable, 450 mm)