Single phase STS keypad prepaid Meter
Infrared communication
international transfer standard
in home display and meter.
Port: SHANGHAI
Minimum Order Quantity: 500 Piece/Pieces
Supply Ability: 50000 Piece/Pieces per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: white box and neutral printing & package(Split prepaid meter, smart meter)
Delivery Detail: 20-25 days after receipt of prepayment
Single phase STS keypad prepaid Meter
Type | Parameter |
Connection mode | Single phase two wire |
Current Sampling | Two Elements(double magnetic) |
Reference Voltage Un | 230V |
Effective Work voltage | 165-240V |
Rated Current Ib | 5A |
Max Current Imax | 60A |
Work Frequency | 50/60HZ |
Starting current | 0.002Ib |
Power Consumption Voltage Element Un Current Element In | <1.5W / <10VA @ Un <2.5 VA @ (Ib) |
Class Accuracy | Class 1 |
Meter Constant | 1000 imp/kWh |
Protection Level | category protection |
Load Control | Two relays with 80A control two elements |
Impulse | LED and Optocoupler output |
Balance indication | Red and Green LED |
Alarm | Yellow LED |
Tamper Indication | Open Top cover/Open terminal cover/ magnetic-field interference/Power reverse/external to earth |
Volume | Buzzer |
Display | 9 segments LCD(7+2) |
Keypad | 3X4 Rubber Button |
LCD Backlight | Optional |
Battery | Built-in battery with large capacitor,power off showed more than 10years |
Communication | IR IEC62056-21A Mode RS485 IEC62056-21A Mode |
2.2 Events Record
Recharge Token last 10 times
Recharge credit last 10times
Recharge time last 10 times
Overload events time last 10times
Power off time last 5times
Open terminal cover time last 5times
Open top cover time last 5times
Tamper electricity time last 5times
Power reverse time last 5times
Balance credit exhaust time last 5times
Note
These events recorded the total numbers of occurred, which the max is 60000times. If L wire and N wire current value more than10%, we estimate it is tampering. Meanwhile, the LED will blink, which will turn off after disappearing events. For other overload events, the LCD will display symbols when occur the opening cover events and reverse events.
Symbols detail reference LCD description.
2.3 Communication function
This meter supports both red-infrared and RS485 two communication methods, the communication protocol according with IEC62056-21, two communication commands are the same. Baud rate:2400(fixed), 7 data digits , 1 even digit, 1 stop digit.
2.4 Token prepaid function
2.4.1 Recharge
The user will get a 20digits TOKEN, then input the token on the meter, when you input the token, the time distance cannot exceed 20seconds between each number, if you input the wrong number, you could press clear away button for modification.
Input the token from the keypad and communication are both ok.