Salt Spray Corrosion Test Chamber
1. According to CNS,ISO,JIS,ASTM
2. Multiple safety protection device
Port: Shenzhen
Minimum Order Quantity: 1 Set/Sets Haida
Supply Ability: 30 Set/Sets per Month Haida
Payment Terms: T/T,Western Union
Contact SupplierPackaging Detail: Strong wooden case
Delivery Detail: 15 days after receive the order
Salt Spray Test Corrosion Chamber adapted to the surface treatment of various materials, including paint, electroplating, organic and inorganic coating, anode processing, antirust oil and so on, after these anti-corrosive treatment to test the corrosion resistance of their products.
Salt Spray Test Corrosion Chamber main technical parameters:
Model | HD-90 |
Inner Box Size (L×W×H) | 90×60×50 cm |
Outside Box Size(L×W×H) | 141×88×128 cm |
Equipment Material | Both inside & outside shell adopt imported P.V.C rigid plastic board, and tank cover uses imported transparent P.V.C. rigid plastic board |
Temperature Range | 35°C~55°C |
Temperature Fluctuations | ≤±0.5°C |
Temperature Uniformity | ≤±2°C |
Temperature Precision | ±1°C |
Test Chamber Temperature | Salt Spray Method (NSS ACSS)35±1°C Corrosion-resistant Testing Method(CASS)50±1°C |
Saturated air Barrel Temperature | Salt Spray Method (NSS ACSS)47±1°C Corrosion-resistant Testing Method(CASS)63±1°C |
Brine Temperature | 35°C±1°C |
Spray Quantity | 1.0~2.0 ml / 80cm2 / hr |
PH | Salt Spray Method (NSS ACSS6.5~7.2) Corrosion-resistant Testing Method(CASS)3.0~3.2 |
Lab Volume | 270L |
Brine Tank Capacity | 25L |
Power | 1#, AC220V,15A |
Multiple Safety Protection Devices | Current discharge protection, over pressure protection,over temperature protection, over load fuse protection |
Accessories | Testing Salt/ Measuring tank/ Equipment each 1 set |
Standard | CNS: 3627, 3385, 4159, 7669, 8886; JIS: D0201, H8502, H8610, K5400, Z2371; ISO: 3768, 3769, 3770; ASTM: B117, B268 |
Salt Spray Test Corrosion Chamber features:
1. Automatic add water when water shortage, with a group of manually water
2. Special glass nozzle, guarantee non-crystalline block for 4000 hours
3. With dual over-temperature protection, water shortage warning, ensure safety use
4. Temperature device adopts digital display, SSR control, precision is 0.1 centigrade degree
5. Chamber adopts direct steam heating method, fast warming, shortening standby time
6. Spray tower attached cone diffuser, with functions of directional mist, adjustable mist, uniformity fog lamp.