Home  >  Analyzers  >  Gas Analyzers

SW-4Q Automobile Exhaust Gas Analyzer

- more info check here: http://www.buymeasuringtools.com/SW-4Q-Automobile-Exhaust-Gas-Analyzer-10193354/

Quick Brief

Product Features:

Business Terms:

Minimum Order Quantity: 1 Set/Sets

Payment Terms: T/T,Western Union

Contact Supplier
SW-4Q Automobile Exhaust Gas Analyzer
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

Specifications

SW-4Q Automobile Exhaust Gas Analyzer

SW-4Q Automobile Exhaust Gas Analyzer

SW-4Q Automobile Exhaust Gas Analyzer (hereinafter referred to as the analyzer) may, in accordance with non-light-disguising infrared absorption method, via micro-computer analysis, directly measure the thickness of HC, CO and CO2in the exhaust gas of vehicles and inspect the density of O2via Electrochemical sensor so as to calculate excess air coefficient λ. The analyzer introduces advanced foreign technology. It is composed of complete imported machinery cores, boasts the advantages of accuracy measurement, high endurance and speed. As an Intelligent Equipment, it is equipped with Microprocessor, LCD and Chinese language interface. Besides, it also has optional equipments such as Induction Tachometer, temperature sensor, inner Micro Printer for customers to purchase. The newly-added Storage function can detect Engine's speed and Lubricant's Temperature while measuring tail gas, then store and print the results.

The main technical parameters:
1. Measurement range:
CO: 0~10.0 10-2(%)
CO2:0~20.0 10-2(%)
HC: 0~10000 10-6(ppm)
O2: 0~25.0 10-2(%)
oil temperature:18150ºC
rotate speed:10020000rpm
2. Repetitiveness: ≤±2%
3. zero floating:
CO: ±0.06 10-2(%)/1h
CO2:±0.5 10-2(%)/1h
HC: ±30 10-6(ppm)/1h
O2: ±0.5 10-2(%)/1h
4. span floating:Not exceed the allowed value for indication error(1 hour).
5. indication error:
CO: ±5% (relative error,010%)
CO2:±5% (relative error,020%)
HC: ±5%(relative error ,04000ppm)±10% (relative error,400110000ppm),
O2: ±5% (relative error,025%)
oil temperature: ±2 (absolute error)
Rotate speed: ±1.0% (relative error)
6. Environmental condition:
temperature:0~40
humidity:≤95%
Air pressure:60~105kPa
power:AC 220V±10%;50Hz
7. preheat time: 5min
8. sampling method:
Directly sampling,the length of the tube is 5M,the length of sampling probe is 900mm.
Oil temperature:inserting the temperature Sensor into Oil Level Gauge of engine, the length of which is the same as that of oil staff gauge; blocking with rubber plug to plug up engine oil from ejecting.
Rotate speed:Non-contact measurement method. Less than 20cm to the petrolic high-voltage flexible cord, measuring the rotate speed of petrolic motor.