Home  >  Electrical Instruments  >  Energy Meters

STE-101C Electric Energy Meter - STE-101C

1. M-BUS protocol, 2.Modbus available, 3.AMR submetering solution, 4.Single phase - more info check here: http://www.buymeasuringtools.com/STE-101C-Electric-Energy-Meter-10022653/

Quick Brief

Place of Origin: Massachusetts United States Brand Name: SHENITECH Model Number: STE-101C Display Type: Digital Only Phase: Single Phase Measuring Energy Range: 40A Accuracy Class: 0.5 / 1 Output Voltage: 120V, 240V Operating Temperature: -10°C - +50°C Dimensions: 130*76*65mm Color: gray

Product Features:

1. M-BUS protocol

2.Modbus available

3.AMR submetering solution

4.Single phase

Business Terms:

Minimum Order Quantity: 100 Set/Sets

Supply Ability: 10000 Unit/Units per Month

Payment Terms: T/T

Contact Supplier
STE-101C Electric Energy Meter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Packaging Type: CartonDimensions:24*20*10

Delivery Detail: Depends on order

Specifications and Product Details:

Performance criteria:

Operating humidity≤ 75%
Storage humidity≤ 95%
Operating temperature-10°C - +50°C
Storage temperature-30°C - +70°C
International standardEN50470-1,EN50470-3
Accuracy class1
Protection against penetration of dust and water IP51
Insulating encased meter of protective class

Meter specifications:

Meter type: STE-101C (LCD display)

Voltage(v)

Nominal voltage AC1×220-230V AC
Voltage range0.7~1.3Un
Insulation capabilities:- AC voltage withstand 2KV for 1 minute
- Impulse voltage withstand 6kV – 1.2µS waveform

Current(A)

Imin0.5
Itr1
Iref(Ib)10
Imax100
Ist40mA

General data

Frequency (Hz)50/60
Frequency range±5%
Accuracy classB(CI..1)

Standards

MID approval according toEN50470-1,EN50470-3
International approval according toIEC62053-11,IEC62053-21
Over current withstand30Imax for 0.01s
Operational frequency range50~60Hz ±10%
Internal power consumption≤2W / 10VA
Test output flash rate (RED LED)1600imp/kWh
Pulse output rate (pins 5 & 6)1600imp/kWh
Reverse indicator (RED LED)Current reverse
Consumption indicator (RED LED)Flashing at load running
Communication indicator (GREEN LDE)Flashing at communication running
Data communication portM-bus
Data saveThe data can be stored more than 20 years when power off

M-bus communication specifications:

Bus typeM-bus
Baud rate300, 2400(default), 9600
Address range≤380m 250PCS

≤3600m 64PCS

Downlink signalMaster to slave, Voltage modulation
Uplink signalslave to master,Current modulation
CableJYSTY (n×2×0.8)
ProtocolEN13757-3
Bus loading256 meters per bus
Range1200m
STE-101C Electric Energy Meter suppliers    STE-101C Electric Energy Meter manufacturers