| Type | ST-2W |
| Accuracy class | C3 OIML R60 // C4 OIML R60 |
| Capacity (Emax) | 10 , 20 T |
| Minimum dead load | 0 %R.O |
| Rated output R.O | 2,0 mV/V |
| Maximum number of load cell interval nmax | 3000 // 4000 |
| Vmin | Emax/10000 // Emax/10000 |
| Emax/Vmin | 10000 // 10000 |
| Minimum dead load output return(MDLOR) | <0,0167 // <0,0125 %R.O |
| Zero balance | 1 %R.O |
| Temperature effect on zero | < 0,0070 // < 0,0070 %R.O/5°C |
| Temperature effect on output | < 0,0055 // < 0,0045 %R.O/5°C |
| Compensated temperature range | -10 /+40 °C |
| Temperature range,safe | -30 /+70 °C |
| Maximum safe central overload | 150 %R.O |
| Ultimate central overload | 300 %R.O |
| Excitation | 5 V |
| Input empedance | 380±20 Ω |
| Output empedance | 350±3 Ω |
| Insulation resistance | >1000 MΩ |
| Conctruction | nickel plated alloy steel |
| Environmental protection | IP67 |
| Cable type | 4x0,22 mm |
| Cable length | 15 m |