SINGLE GAS ALERT MONITOR
Dual Display of Gas Concentration & Set Point / Unit of Gas
Port: Mumbai.
Minimum Order Quantity: 1 Unit/Units
Supply Ability: 400 Unit/Units per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: Standard Thermocol & cartoon packing. For Export order wooden packing are available on request
Delivery Detail: 1 week.
SINGLE GAS ALERT MONITOR
FEATURES:
APPLICATIONS:
TECHNICAL SPECIFICATION | ||
Input | 4 to 20mA output from Oxygen / Toxic / Combustible Gase Transmitters | |
Range | 0 to 9999 In units of P.P.M. OR % L.E.L. OR % VOL. programmable by user | |
Resolution | 1 / 0.1 Resolution programmable by user | |
Accuracy | ± 1% of the full scale value | |
Dual Display | 1) Upper :- 4 Digit of 13mm(H) Red LED display for 'Gas Concentration' indication 2) Lower :- 4 Digit of 13mm(H) Red LED display for 'Set Point Value' of Alarm Relay-1/ Unit of Gas | |
LED Indication | AL1 & AL2 for Relay, FLT for Fail-Safe Relay, PRG for Programming mode, INB for Service / Inhibit mode, TST for Test mode, TX for Transmitting signal, RX for Receiving signal | |
Set point | 2 No, Independent set point for Alarm Relay-1 & Alarm Relay-2 with programmable latch & non- latch facility | |
Control Action | LO / HI, HI / LO, LO / Very LO, HI / Very HI, Programmable by user | |
Hysteresis | 0 to 100 counts, Individual setting for Alarm Relay-1 & Alarm Relay-2, Programmable by user | |
Time Delay | Independent Programmable 0 to 9999 sec for Alarm Relay-1 & Alarm Relay-2 | |
Relay Output | Alarm Relay-1 operates for set point 1, Alarm Relay-2 operates for set point 2 & Fail-Safe Relay with normally-off or normally- on conditions selectable | |
Relay Contact type | 3 No, 1 NO-C- NC, 230 VAC/5A Relay contact for RL1, RL2 & Fail-Safe Relay | |
Setting | Setting by 4 keys on front panel i.e. 'SET / NEXT', 'UP', 'DOWN' & 'TEST / BACK' | |
Monitoring | i)By display : Sensor break/ open shows 'oPEn', under range shows 'Undr' & over range shows 'ouEr' ii) By Retransmission current : Upscale current : 21mA, Down scale current : 3mA, Programmable | |
Supply Voltage | 230 VAC ± 10% OR 110 VAC ± 10% OR 24 VDC | |
Cable | 1.5 sq. mm 3 Core OR 2 Core, Flexible OR Armoured shielded cable from Gas transmitter | |
Operating Temperature | 0 to 50°C ± 5%, Relative Humidity: Below 95% non Condensing | |
Enclosure Detail | GM - 1100 - WP (Weatherproof ) | GM - 1100 - FLP(Flameproof ) |
Protection Class | IP-65 | IP-65 for Gas Gr. IIA & IIB, CCOE & CMRI Approved |
Cabinet Material | Polycarbonate, gray colour | Cast Aluminum alloy, LM-6 / C.I. Enclosure |
Cable Entry | Thermoplastic cable gland (IP 68) with clamping range of 2.5 to 6.5mm | Double compression cable gland (Ex-Proof), ¾ ET type |
Dimension | 250 (H) x 290 (W) x 145 (D) in mm | 350 (H) x 290 (W) x 170 (D) in mm |
Mounting | Wall Mounting / Stand Mounting | Wall Mounting / Stand Mounting |
Weight | Approx 2.5 kg | Approx 5.0 kg |
Optional | a) Isolated RS-485 Serial port with MODBUS RTU protocol output b) SMARTLOG / SCADA SOFTWARE for online graph & data report for safety Audit c) Flame Proof or Non Flame Proof Industrial Hooter, Hooter cum Flasher, Chart recorder, Cables, PC software, Gas Transmitter, 24VDC power supply, Gas calibration kit d) Optional programmable linear 4-20mA / 20-4 mA O/P with respect to Gas concentration range |