Home  >  Analyzers  >  Moisture Meters

Room Humidity Transmitters 5% or 3% indicates - RH-5U-R

Indoor Humidity measurement/ Room Humidity Transmitters., Wide range of temperature probes, 0-10V or 4-20mA - more info check here: http://www.buymeasuringtools.com/Room-Humidity-Transmitters-5-or-3-indicates-10064888/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: CH-BA Model Number: RH-5U-R 0-10V or 4-20mA: 0-50 degree C

Product Features:

Indoor Humidity measurement/ Room Humidity Transmitters.

Wide range of temperature probes

0-10V or 4-20mA

Business Terms:

Port: Shanghai

Minimum Order Quantity: 50 Piece/Pieces

Supply Ability: 500 Piece/Pieces per Month

Payment Terms: L/C,T/T,Western Union

Contact Supplier
Room Humidity Transmitters 5% or 3% indicates
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

Features

Room Humidity Transmitters

· Indoor Humidity measurement.

· Wide range of temperature probes

· 0-10V or 4-20mA measuring signals

· Compact size and modern design

Applications

· Indoor humidity measurement for comfort control

Humidity Tansmitter

The transmitter measures the humidity by the honeywell humidity sensor HIH-3610. The transmitter analog output may be be 0-10V or 4-20mA. And the transmitter include a noise filter.the power suply is large range VDC18V----VDC30V.The humidity transmitter measurement range is 5%-95%.

Ordering

Ordering number:RH-5U-R or RH-5U-R-T

-5 indicates the humidity transmitter accuracy is 5%; -3 indicates 3%, -2 indicates 2%.

-U indicates the humiditt transmitter signal out is 4-20mA or 0-10V optional.

-T indicates the humidity transmitter integration with temperature signal out.

For example:RH-5U-R-T

The room humidity and temperature transmitter signal out is 4-20mA or 0-10V optional .

Installation

Mount the humidity transmitter on a flat interior wall of the room to be controlled. Do avoid obstructions such as shelves, curtains and recesses. Do not place near heat sources, draft channels. Do not expose to direct sunlight.

· When installing the unit, fix the base plate first, connect the electrical connections then hook on the cover and secure it.

· The end of the conduit at the sensor must be sealed to prevent false measurements due to draughts through the conduit.

· Connect the wires according to the wiring diagram to the measuring circuit in the cover:

o If only humidity, the transmitter need three terminal connections,DC24V,Ground and humidity signal out.

o If humidity and temperature, the transmitter need four terminal connections, DC24V,Ground , humidity signal out and temperature signal out .

o The connection signal cable should be shield wires.

Technical Specification

Power suply

Option voltageVDC18V---VDC30V
Power CunsumptionMax 2 VA

Signal out

signal4-20mA or 0-10V
Humudity accuracy5%
Humudity range0%-100%
Temperature accuracy0.5 degree C
Temperature range0-50 degree C
Sensing elementCapacitive Element:

Range

Accuracy

5%---95%

2%

ConnectionConnection Terminals2.5 mm2

Environment

Operation
Climatic Conditions
Temperature
Humidity
To IEC 721-3-3
class 3 K5
-4070°C
<95% r.h.
Transport & Storage
Climatic Conditions
Temperature
Humidity
Mechanical Conditions
To IEC 721-3-2 and IEC 721-3-1
class 3 K3 and class 1 K3
-4080°C
<95% r.h.
class 2M2

Standards

conform according to
EMC Standard 89/336/EEC
EMEI Standard 73/23/EEC

EN 61 000-6-1/ EN 61 000-6-3
Automatic electrical controls for household and similar use

Special requirement on temperature dependent controls

EN 60 730 1

EN 60 730 2 - 9

Pollution ClassNormal acc. To EN 60 730,RoHS compliant
Degree of ProtectionIP56 to EN 60 529
Safety ClassIII (IEC 60536)
Housing MaterialsCover & Mounting PlateFire proof ABS plastic

General

Dimensions [mm]Cover: 42 x 112 x 88 (H x W x D)

probe: ø 10 x 200 (Diameter x L)

Weight (including package)135g