Radiation detector
Port: shenyang china
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 1000 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: carton
Delivery Detail: 10 day
[Material]LCD screen,double-sided circuit design,low power IC. SCM system management. G-M radiological special high sensitivity test tube,Lithium battery power.
[Technique Data]
1. Radiation measuring range(βΧγ): 0.01µsv/h ~9999.99µsv/h.
2.Radiation sensitivity :not less than0.03Mev.
3. Working voltage: DC3.6V
4.Testing environment temperature:-40°C~50°C
5. Voice alarm radiation dose: begin above 1µsv/h
6. Pulse dose rate: 1cps~65530cps
7.Lifetime: 10000Mcp.
8. Charging: Universal DC4.2 V Lithium battery charger
9. Batteries: lithium batteries. Uninterrupted detection while recharging, ensure the environment monitoring of whole day
10.Standby time:not less than100hours
11.Language: bilingual broadcast (Chinese and English)on radiation hints..
12 Shell dimension:155mm×75mm×35mm
[operating instruction]
1.LCD first row is English :PM—elcamulet
2. LCD second row is Radiation dose display: 0.01µsv/h~9999.99µsv/h
3. LCD third row is Pulse dose display: 1cps~65530cps
4. LCD Forth line in turn is device working indicator icon, Radiation indicator icon, power indicator icon:
a. Device working indicator icon: The small bulb icon flashing when the device working:
b. Radiation indicator icon move from left to right: The screen will light when there is voice alarm, and the four radiation icon will flash rapidly;
c. Power indicator icon: The grid in the battery icon will decline when the battery power is low,the yellow grid will rise when charging; the indicator will turn red and flashing fast when the battery power is low,both with voice alarm,please charging as soon as possible.
5. There is Double color LED tube under the LCD screen. Give green light when working,give red light and flash when the power is low. There is LCD backlighting switch button under the LED, press it when you can't see the word clearly, then LCD backlighting will light for 60 seconds. Voice alarm will be only once, if want to continue listening the voice alarm,please press the backlighting switch button.
6. On the Bottom of the instrument, there is the power switch, and the Side socket is charging outlet .The LCD screen will light and display radiation dose and pulse dose value when detected radiation, please press the backlighting button when measuring ultra low radiation, so that easy to observe value.
[note]
1. When using avoids strong vibration, Powerful electromagnetic wave environment and water vapor environment.
2. The indicator give red light when the charger is charging, turn green when full of power. Please make it filled with electricity and turn off the power switch when you don't use it for a long term. Suggest charging once a quarter of a year when not using for extending the lifetime of the battery.