Beta, Gamma, X-rays radiation counters. Genuine Russian origin (English menu) RADEX1706,1008
Minimum Order Quantity: 1 Unit/Units
Supply Ability: 500 Unit/Units per Month
Payment Terms: T/T,Western Union
Contact SupplierPackaging Detail: 1pcs per box, 10/20pcs per carton
Delivery Detail: November 30, December 15
Specifications (comparison table) of RD1503,1503+,1706
Technical specifications | RD1503 | RD1503+ | RD1706 | |
Range of ambient dose rate equivalent | µSv/h | from 0.05 to 9.99 | from 0.05 to 9.99 | from 0.05 to 999 |
Range of exposition dose rate | µRem/h | from 5 to 999 | from 5 to 999 | - |
Range of registered gamma radiation energy | MeV | from 0,1 to 1,25 | from 0,1 to 1,25 | from 0,1 to 1,25 |
Range of registered X-ray radiation energy | MeV | - | - | from 0,03 to 3,0 |
Range of registered beta radiation energy | MeV | - | - | from 0,25 to 3,5 |
Reproducibility of indications (at confidential probability 0.95) where P is a doze rate in µSv/h | % | 15+6/P | 15+6/P | 7+6/P |
Threshold levels | µSv/h | 0.30, 0.60, 1.20 | 0.10, 0.20, 0.30, 0.40, 0.50, 0.60, 0.70, 0.80, 0.90 | from 0.1 to 99,0 |
µRem/h | 30, 60,120 | 10, 20, 30, 40, 50, 60, 70, 80, 90 | - | |
Time of calculation | sec. | 40 ± 0.5 * | 40 ± 0.5 * | from 26 to 1 ** |
Time of indication | - | continuously | continuously | continuously |
Batteries of "AAA" type | pieces. | one or two | one or two | one or two |
Time of continuous work of a device, not less | hour. | 550 ** | 550 *** | 500 *** |
Specifications of RD1008
Range of dose rate measurement | mcSv/h | from 0.1 up to 999 |
Range of flux density measurement | 1/(cm*2min) | from 6 up to 999 |
Range of dose measurement | mSv | from 0,001 up to 999 |
Range of energies of the registered: | ||
photon ionizing radiation | MeV | from 0,05 to 3,0 |
beta-radiation | MeV | from 0,05 to 3,0 |
Random error with confidence probability 0,95 (reproducibility of the results): | ||
of dose rate , not more, where N is the dose rate in mcSv/h | % | ±(15+3/H) |
of flux density, not more, where R is the flux density, 1/cm2* min | % | ±(20+200/R) |
of dose, not more | % | 15 |
Range of sound alarm thresholds of: | ||
dose rate | mcSv/h | from 0,20 to 1,20 |
flux density | 1/cm2*min | from 10 to 12 |
time of measurement of: | ||
dose rate | s | from 1 to 21(1) |
flow density | s | |
Power supply: "AA" type battery | pc | 1 |
Time of continuous work of the devise | min h | 950 (2) |
Price-list:
Quantity, pcs | Price, US$ RADEX1706 | Price, US$ RADEX1008 | Shipment / Delivery | Pre-payment, % | Method of Payment | ||
Sample 1-10 | $ 400 | $ 610 | DHL/EMS | 100 | Western Union | ||
11-50 | $ 380 | $ 510 | DHL/EMS | 100 | Bank Transfer (Contract) | ||
51 - 100 | $ 270 | $ 380 | DHL/EMS | 100 | Bank Transfer (Contract) | ||
101 -200 | $ 250 | $ 350 | DHL/EMS | 100 | Bank Transfer (Contract) | ||
201 and up | $ 235 | $ 335 | DHL/EMS | 100% | Bank Tranfer(Contract) | ||
Price does not include shipment. |