RH2000 Online monitoring station; online monitoring system; continuous monitoring system
Port: Shanghai
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 500 Set/Sets per Week
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: At clients' option
Delivery Detail: According to the quantity
RH2000 Online monitoring station
Powerful calculation capability, users can set multy monitoring parameter and alarming condition.
Realize longdistance diagnosis of equipment, the data of any channels can be tansfered to computer and display graphs of spectrum, waveform and trend chart etc.
The dustproof and waterproof system can satisfy various industrial environment using, small volumn is convenient for installing as well.
Good scalability, convenient for networking, the system features are not influenced by increasing of collection module.
The main features of online monitoring analysis system is suitable for the key machinery of production line to realize integrated online monitoring and diagnosis. It can integrate various online monitoring technology, synchronously collect and monitor the signals of vibration, rotating, temperature, motor current, torsion, various process information and switching value.
Vibration channels compatible with voltage and current, assembled safety and low voltage 24V@4mA constant-current source for ICP accelerometer.
The tacho channel is compatible with multi rotational velocity transducer,including photoelectric sensor, eddy current type transducer, Hall Sensor etc.
technical parameter
Maximal inout Channels | 24 channels for vibration, 12 channels for process information, 8 channels for tacho. | ||
Vibration signal input | |||
Channels | Max. 24 channels | 4,8,12,16,20,24 optional | |
Synchronous measurement | Multy-channels synchronously collection | ||
Compatible transducers | Accelerometer, Velocity, Displacement, Voltage 4-20mA. | ||
Envelope demodulation | 500,2K,5K,16K | ||
Signal Range | ±24V | ||
Transducer driver current | 4mA@24V | Constant current source used for ICP acclerometer | |
A/D conversion | 16 bit | ||
Input impedance | 220K | ||
Physical quantity | Acceleration, Velocity, Displacement, user-specified | ||
Integral | Integration, double integration | ||
Accelerometer maximum | 80g, 200mm/s, 10mm | use 100mV/g transducer | |
Spectrum Fmax | 100Hz – 40kHz | 20 grade | |
Sampling rate | 256Hz – 102.4kHz | 20 grade | |
Dynamic signal range | 95dB | ||
Harmonic distortion | <-70dB | Other distortion and noise will be lower | |
Precision | 1%( 0.1dB) | 80Hz | |
Frequency response | 0.2dB, 10Hz – 5kHz 0.5dB, 3Hz – 20kHz | Use 80Hz as reference | |
Lines | 400,800,1600,3200,6400,12800 | ||
Time domain sampling | 1024,2048,4096,8192,16384,32768 | ||
Continuous sampling | Long time continuous sampling | ||
Window function type | Hanning, Rectangle | ||
Averaging type | Linearity, peak hold | ||
Averaging times | 1,2,4,8,16,32,64 | ||
Process information | |||
Channels | 16, Isolation input | ||
Signal range | ±12V or 4~20mA | ||
Switching value | |||
Channels | 8, Isolation input | ||
Signal range | 5V level | ||
Rotating speed | |||
Channels | 8 | ||
Compatible type | TTL, Eddy current, Hall | ||
Triggering level | ±2V~±30Vpp | ||
Regular index | |||
Communications | Ethernet v2.0. IEEE802.3, TCP/IP, 10/100baseT | ||
Storage capacity | 512M | ||
Dimensions | 600×400×180, Stainless steel shell | ||
Protection grade | IP65, dustproof, waterproof | ||
Temperature range | (-20 – 55)°C | ||
Humidity | 95% RH without condensate |