Temperature Controller / thermostat for cold room
1. two 10NTC sensors
2. Temp. range: -50~110C
3. Power: 110V / 220VAC
Minimum Order Quantity: 100 Piece/Pieces
Supply Ability: 1000 Piece/Pieces per Week
Payment Terms: T/T,Western Union,PAYPAL
Contact SupplierPackaging Detail: carton
Delivery Detail: consult
owns two 10K NTC sensors, RC-321M digital thermostat is a full capability digital temperature controller, could control both heating and refrigeratio, defrost, fan; in one device,
1) cooling control: yes
2) heating control: yes
3) compressor control: yes
4) defrost control: yes
5) fan control: yes
6) Temperature alarming: yes
7) forcible refrigeration function so as to preventing freezer burn
Function | Description |
Temp. Range (°C) | -50 ~ +110 |
Temp. Rectification (°C) | -10 ~ +10 |
Heating | Yes |
Cooling | Yes |
Temp. Alarm | Yes |
Defrost Controlling | Yes |
Fan Controlling | Yes |
Gross Weight (g/PCS) | 288 |
Item | Description |
Mount Size | 75mm×29mm |
Product Size | 75mm×34.5mm×85mm |
Accuracy | ±1 °C |
Precision | 0.1 °C |
Ambient temperature | -10 ~ +60°C |
Ambient humidity | 20% ~ 85% |
Power consumption | 3 ~ 5W |
Sensor Type | 2 PCS 10K NTC |
Voltage | Unit | MOQ |
220V ± 10%, 50/60 HZ | °C | 1 PCS |
°F | 100 PCS | |
Other Voltage | °C | 100 PCS |
°F | 100 PCS |
Heating function menu
CODE | FUNCTION | RANGE OF SETTING | DEFAULT | UNIT |
F00 | Mode option | 00: refrigeration; 01: heating | ||
F01 | Start up Temp. | F02 ~ 110 | -8 | °C |
F02 | Shut down Temp. | F01 ~ 110 | -10 | °C |
F03 | Compressor delay | 0 ~ 20 | 3 | Min. |
F04 | High temp. alarm | 0 ~ 50 | 50 | °C |
F05 | Low temp. alarm | 0 ~ 50 | 50 | °C |
F06 | Temp calibration | -10 ~ 10 | 0 | °C |
Refrigeration function menu
CODE | FUNCTION | RANGE OF SETTING | DEFAULT | UNIT |
F00 | Mode Option | 00: refrigeration 01: heating | ||
F01 | Start up Temp. | F02 ~ 110 | -8 | °C |
F02 | Shut down Temp. | -50 ~ F01 | -10 | °C |
F03 | Compressor delay | 0 ~ 20 | 3 | Min. |
F04 | High temp. alarm | 1 ~ 50 | 50 | °C |
F05 | Low temp. alarm | 1 ~ 50 | 50 | °C |
F06 | Temp calibration | -10 ~ 10 | 00 | °C |
F07 | Defrost cycle | 0 ~ 99 | 6 | Hr. |
F08 | Defrost time | 0 ~ 99 | 30 | Min |
F09 | Defrost duration | 0 ~ 20 | 3 | Min |
F10 | Defrost mode | 00:Electric-Heating; 01: Thermal | 00 | / |
F11 | Defrost display | 00: Real-Time Temp.; 01: Departed Temp. | 00 | °C |
F12 | Forcible refrigeration | F02 ~ 110 | 30 | / |
F13 | Defrost stop temp. | 0 ~ 110 | 50 | °C |
F14 | Fan mode | 00: start and stop with compressor simultaneously, stop running when defrosting; 01: operation continually, controlled by F13 | 00 | / |
F15 | Fan stop temp. | -50 ~ 110 | 10 | °C |
F16 | Communication signal | 000 ~ 999 | 000 | °C |