Process signal calibrator
1.Manual/automatic cool terminal compensation
2.Automatic triangle
3.Ramp wave output
Port: Beijing/Tianjin
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 100 Set/Sets per Month
Payment Terms: L/C,T/T,Western Union
Contact SupplierPackaging Detail: standard export package
Delivery Detail: 4-8weeks
Portable process signal calibrator ZH556D
Features:
1. Measurement/simulation
DC voltage measurement: DC 0~20V generation:DC 0~10V
DC current: 0~24 mA
mv:0~100 mV
Resistance:0~3200Ω
Frequency :1~50 kHz, square wave, sin wave
Thermal resistance:Pt100,Pt200,Pt500,Pt500,Ni120,Pt1000,Pt3926,Pt3916
Thermal couple:J,K,T,E,R,S,B,L,U,N
Pressure signal:2500Pa~20MPa,extended digital pressure module
5-1/2bit display: zero/full scale self-calibration
2. Manual/automatic cool terminal compensation and set; automatic triangle, ramp wave output
Series products:
1.ZH556D-25multi-function process signal calibrator
2.ZH556D-12thermal resistance calibrator
3.ZH556D-13 thermal couple calibrator
4.ZH556D-15 pressure calibrator
5.ZH556D-16 frequency signal calibrator
6.ZH556D-17 current,voltage/loop calibrator
Technical specifications:
1.Current/voltage output
type | resolution | accuracy(RD%+COUNTS) | note |
-10~100mV | 0.01 mV | 0.01%+COUNTS | Max load current1mA |
0~10V | 0.01V | 0.01%+COUNTS | Max load current1mA |
0~24mA | 0.001mA | 0.01%+COUNTS | Max load resistance 100Ω |
Temperature coefficient :-10°C~18°C,+28°C~55°C,(0.001%RD+0.003%FS)/°C |
2.resistance output
type | resolution | accuracy(RD%+COUNTS) | note |
5~400Ω | 0.1Ω | 0.015%+0.1Ω | Drive current 0.1~0.5mA |
0.05Ω | 0.015%+0.05Ω | Drive current 0.5~3.0mA | |
400~1500Ω | 0.5Ω | 0.015%+0.5Ω | Drive current 0.05~0.8mA |
1500Ω~3200Ω | 0.5Ω | 0.015%+0.5Ω | Drive current 0.05~0.4mA |
Temperature coefficient -10°C~18°C,+28°C~55°C,0.015%FS/°C |
3.Frequency signal output
type | resolution | accuracy | note |
1~1100HZ | 0.1HZ | ±0.05% | / |
1.0~10.0KHZ | 0.01KHZ | ±0.1% | / |
10.0~15.0KHZ | 0.01KHZ | ±0.5% | / |
Output wave:square,adjustable duty cycle,amplitude:1V~10Vp-p,offset:-0.1V Max load current:1mA |
4.current loop/ voltage source
type | resolution | accuracy(RD%+COUNTS) | note |
Current measuement(LOOP) | 0.001mA | 0.01%~0.015% | / |
24V output | / | 10% | Max load current 50mA |
Temperature coefficient:-10°C~18°C,+28°C~55°C,(0.001%RD+0.003%FS)/°C |
5.thermal couple (Details were omitted because that the describe space is insufficient)
6.thermal resistance(Details were omitted because that the describe space is insufficient)
7.voltage/current signal measurement(Details were omitted because that the describe space is insufficient)
8.resistance measurement(Details were omitted because that the describe space is insufficient)
9.frequency signal measurement(Details were omitted because that the describe space is insufficient)
10.thermal couple measurement(Details were omitted because that the describe space is insufficient)
11. thermal resistance measurement(Details were omitted because that the describe space is insufficient)
12. size: 290mm*220mm*90mm
13. weight :1.7kg