Home  >  Temperature Instruments

Process V/mA Calibrator - VC15+

process calibrator, Voltage/mA Calibrator, Temperature Calibrator, Process Source Calibrator, Temperature Simulator Calibrator - more info check here: http://www.buymeasuringtools.com/Process-V-mA-Calibrator-10018586/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: TOTAL Model Number: VC15+

Product Features:

process calibrator, Voltage/mA Calibrator, Temperature Calibrator, Process Source Calibrator, Temperature Simulator Calibrator

Business Terms:

Port: SHANGHAI

Payment Terms: L/C,T/T,Western Union

Contact Supplier
Process V/mA Calibrator
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

We producing process calibrator, Voltage/mA Calibrator, Temperature Calibrator, Process Source Calibrator, Temperature Simulator Calibrator, Thermocouple Calibrator, RTD Calibrator, Loop Calibrator.

VC15+V/mA Calibrator

Features: High Accuracy of 0.02% for measure and source. 5 digits display for measure, and 6 digits display for
source.A dual, Liquid Crystal;Display White LED for backlight

TECHNICAL DATA (Output Function)

FunctionReferenceRangeResolutionAccuracyRemark
DC voltage1000mV-100.001100.00mV10μV0.02+0.01Maximum output: 2mA
10V-1.000011.0000V0.1mV0.02+0.01Maximum output: 5mA
DC current20mA0.00022.000mA1μA0.02+0.02Simulator transmitter: 528V power
supply outside;1KΩ at 20mA
FREQ100Hz1.00Hz110.00Hz0.01Hz±2 countOutput voltage: +1+11 V (zero
base waveform);
Amplitude accuracy: ±10%+0.5V;
Maximum load: >100 KΩ;
Duty Cycle: 50%.
1KHz0.100KHz1.100KHz1Hz
10KHz1.0KHz11.0KHz0.1KHz
PULSE100Hz1100000cycles1cyc
1KHz
10KHz
LOOP24V±10%Maximum output current: 25 mA
Short circuit protected

Measuring Function
FunctionReferenceRangeResolutionAccuracyRemark
DCV-20.00220.00mV10μV0.02+0.02-20.00220.00mVInput Resistanceapproximately 100MΩ
Input Resistance approximately 1MΩ
-0.50005.5000V0.1mV0.02+0.01-0.50005.5000V
-5.00055.000V1mV0.03+0.01-5.00055.000V
DCmA50mA-4.00055.000mA1μA0.02+0.01Input Resistance5Ω
FREQ500Hz3Hz500.00Hz0.01Hz±2countInput Impedance100 kΩ at least;
Sensitivity3Vp-p minimum;
Duty Cycle: 50%.
5KHz3Hz5.0000KHz0.1Hz
50KHz3Hz50.000KHz1Hz
CONTINUITY≤250Ω soundCLOSE / OPENOpen circuit voltage:about 2.5V
PRESSDefined by
pressure module
Defined by
pressure module
Defined by pressu-
re module
For more detail, refer the pressure
module about APM.



General Characters
Power4×1.5AAA-size alkaline batteries (AC adapter can charge Ni-Hi battery)
Max.allowable voltage30V
Operation temperture range0-50°C
Operation humidity range≤80%RH
Store temperature range≤-10°C-55°C
Store humidity range≤90%RH
Size205×95×42mm
Weight500g(with holster)
AccessoriesTest leads,Fuse
OptionsAC adapter(VCPS),
SecurityConforms to IEC 1010

Process V/mA Calibrator suppliers    Process V/mA Calibrator manufacturers