Home  >  Analyzers  >  PH Meters

Portable Pen type PH Testing meter - PH-009(I)A

1.Use to test potential of hydrogen of water, 2.The range is from 0.0~14.0 OPH, 3.With pen type design, 4.Very portable - more info check here: http://www.buymeasuringtools.com/Portable-Pen-type-PH-Testing-meter-10263581/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: 0 Model Number: PH-009(I)A Range: 0.0-14.0PH Resolution: 0.1PH Accuracy: ±0.1PH Temperature compensation: 0-50 centigrade Battery: 4X1.5V(AG-13) Operating temperature: 0-50 centigrade Dimensions: 150mmx29mmx20mm Weight: 51g Color: Yellow

Product Features:

1.Use to test potential of hydrogen of water

2.The range is from 0.0~14.0 OPH

3.With pen type design

4.Very portable

Business Terms:

Port: shekou

Minimum Order Quantity: 1000 Piece/Pieces

Supply Ability: 2000 Piece/Pieces per Day

Payment Terms: D/P,T/T

Contact Supplier
Portable Pen type PH Testing meter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: 0

Delivery Detail: 15 days after receiving the paymental of goods.

Specifications and Product Details:

Portable Pen type PH Testing meter

The main parameters of PH meter

Range0.0-14.0PH
Resolution0.1PH
Accuracy±0.1PH
Temperature compensation0-50 centigrade
Battery4x 1.5v (AG-13)
Operating temperature0-50 centigrade
Dimensions150mmx29mmx20mm
Weight51g

PH Meter calibration

1.immerse the electode in PH 6.86(under the temperature of 25centigrade)

standard buffer solution of phosphate, and gently shake the electrode.

2.Regulate the trimmer with a screwdriver until the buffer solution value

corresponding to the measurement temperature is obtained.

3.Immerse the electrode in PH 4.01 or PH 9.18 the standard buffer solution of borax.

4.After about one minute,until the buffer solution value corresponding to the

measurement temperature is obtained.

OPERATION :

1.remove the protective cap.

2.First clean the electrode with distilled water,and suck it with filter paper.

3.Turn on PH by "NO-OFF"switch located on the top of battery case.

4.Immerse the PH meter electrode in solution up to the immersion level.under

no circumstances immerse above display level.

5.Stir gently and wait for the reading to stabilize.

6.After use,switch off it,use the distilled water clean the electrode

and replace the protective cap.