Portable gas Analyzer
Port: JNPT Navi Mumbai
Minimum Order Quantity: 1 Unit/Units As Per Order
Supply Ability: 50 Unit/Units per Week As Per Order
Payment Terms: T/T
Contact SupplierPackaging Detail: Export Quality Packing
Delivery Detail: 2 weeks
Infrared Flue Gas Analyzer – Portable
Model: CIFGA-P-SO2/NO/CO/CO2/O2
Portable Infrared Flue Gas Analyzer measures the concentration of gases like SO2,NO, CO, CO2,O2(5 gases)simultaneously in a gas sample with optional measurement of gas temperature, pressure & flow testing function. Measurement of SO2,NO, CO & CO2is based on Micro Flow NDIR (Non Dispersive Infrared) method & O2is based on Electro Chemical Detector (ECD).
This portable instrument is used for combustion and emission control research and evaluation of continuous emission monitoring system. Also used for monitoring of combustion efficiency of industrial furnaces, boilers and refuse incinerators.
Features:
Ø Based on micro flow NDIR gas sensor technology. Optional Catalytic NOxconverter (for NO2to NO conversion in ppm range)
Ø Measures concentration of SO2,NO, CO, CO2&O2 -5 gases simultaneously.
Ø Measurement of temperature, pressure and flow function of gases (Optional).
Ø Moisture in the sample does not effect SO2& NO measurement.
Ø Zero calibration with fresh air.
Ø Sampling pump (Optional).
Ø Graphical (320x240) LCD with backlite.
Ø Calculation of combustion efficiency.
Ø RS-232 Interface.
Ø Work on AC adopter & battery. Battery gets charged while instrument is powered through AC adopter.
Gas Concentration Measurement
Measuring Gas | Technology | Range | Resolution | Accuracy |
SO2 | Micro Flow NDIR | 0-2000ppm | 1 ppm | +1% |
NO | Micro Flow NDIR | 0-2000ppm | 1 ppm | +1% |
CO | Micro Flow NDIR | 0-5000ppm | 1 ppm | +1% |
CO2 | NDIR | 0-25% | 0.01% | +1% |
O2 | ECD | 0-25% | 0.01% | +3% |
NOx (Optional) | Catalytic Gas Conversion | 0-5000ppm | 1ppm | +2% |
Temperature Measurement
Parameter | Measuring Device | Measuring Range | Resolution | Accuracy |
Flue Gas Temperature | Thermocouple | -10~600°C | 1°C | +2°C |
Ambient Air temperature | Thermistor | -10~100°C | 1°C | +1°C |
Pressure Measurement
Parameter | Measuring Device | Measuring Range | Resolution | Accuracy |
Differential Pressure | Silicon Differential Pressure Chip | -50hPa~50hPa | 1Pa | +2Pa |
Ambient Pressure | Silicon Pressure Chip | 70kPa~120kPa | 0.01kPa | +0.5kPa |
Flow Rate Measurement
Parameter | Measuring Device | Measuring Range | Resolution | Accuracy |
Flowrate | Pilot tube | 3~40m/s | 0.1m/s | +2.5% FS |
Specifications
Sampling gas requirement :Free from dust, water vapour and oil.
Flow rate :0.7~1.2 ltr/min
Inlet pressure :2kPa~50kPa
Response time :15 secs
Power Supply :AC 220+10%V, 50Hz, Inbuilt Li-ion Battery.
Temperature :0~50oC
Relative Humidity : 85%
Ambient Air Pressure :86~108kPa
Dimensions :450(L) x 350(W) x 180(H) mm
Weight :10kg
Accessories
Heated sampling Probe, Gas Conditioning system with NOxConverter, Heated Line
Heated sampling probe temperature :120 – 160oC
Optional Sampling pipe and pilot tube length :1.7m
Heated line : 3m
NOxConverter: >95%
Dehumidifier temperature: < 4oC