BANTE8 series Portable Dissolved Oxygen Meter
Port: ANY PORT IN CHINA
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 10000 Set/Sets per Month
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: CARTON PACKING
Delivery Detail: WITHIN 30-45DAYS AFTER RECEIVE THE PAYMENT
BANTE8 series Portable Dissolved Oxygen Meter
BANTE8 series meters use polarographic electrode to measures dissolved oxygen in water, it can display the oxygen level as % saturation from 0 to 200% or concentration from 0 to 20ppm (mg/L).
Automatic Calibration:
The meters can be calibrated at one or two points - in air (100%) and/or with a zero oxygen solution, easy and quick calibration ensures accurate reading.
Auto-Calibration Recognition:
During calibration, if the calibration condition does not match the meter's requirement, an ERROR message is displayed.
Automatic Temperature Compensation:
The DO probe with a globular shape temperature sensor, it can provides automatic temperature compensation to ensure accurate measuring value.
Salinity and Barometric Pressure Compensation:
Salt dissolved in solution limits oxygen content, BANTE 8 series meters can compensates salinity and barometric pressure after manual input coefficients.
Multi-measurement Units:
The meters can choose the various units for different countries. Example: mg/L vs. ppm; kPa vs. mmHg. Degrees. C vs. F, and so on.
Hold Function:
To keep the latest measurement on the display, after taking a reading press the HOLD key and the measurement remains on the display, You can easily view and record data.
Save and Communication Interface:
BANTE8 series all have real-time date/clock stamps, The memory stores up to 48 discrete data sets. Press the SAVE key to store the current measured values and it automatically generates a serial number with the date and time. This data can then be sent to a computer via the USB port.
Specifications:
Model: BANTE820
Dissolved Oxygen Range: 0.0 to 20.0mg/L or ppm
Resolution: 0.1mg/L
Dissolved Oxygen Accuracy: ±0.5mg/L
% Saturation of Oxygen: 0.0 to 200.0%
Accuracy: ±10.00%
Temperature Range: 0.0 to 50.0oC, 32 to 122oF
Temperature Accuracy: ±1oC, ±1.8oF
Temperature Compensation: 0.0 to 40.0oC, Automatic
Salinity Correction: 0 to 35g/L
Barometric Pressure Correction: 450 to 50mmHg, 60.0 to 112.5kPa
Calibration Points: 1 or 2 points, 100% in air or 0% in solution
Memory: 48 data sets with Date/Time stamping
Output: USB communication interface
Power Requirements: 9V Battery
Dimensions: 185(L)×88(W)×32(H)mm
Weight: 300g