Payment-controlled Smart Electricity Meter;
Pre-payment;
Three-phase;
Payment-controlled Smart Electricity Meter;
Port: Guangdong
Minimum Order Quantity: Negotiable
Supply Ability: 1,000,000 Unit/Units per Year
Payment Terms: L/C,D/A,D/P,T/T,Western Union
Contact SupplierPackaging Detail: In cartons with different demensions for different types of meters
Delivery Detail: Subject to technical requirements and amount of order
Three-phase Payment-controlled Smart Electricity Meter
Introduction of the product
Three-phase payment-controlled smart electricity meter has a variety of types and configurations, such as carrier or non-carrier; CPU card, RF card or remote; external switch or internal switch, etc. All products have adopted large-scale integrated circuit, digital sampling technology and SMT technology. They have embedded AC voltage and current acquisition module with high speed and precision, which can accomplish high-precision sampling, as well as real-time accurate power measurement; meanwhile they encompass such functions as pre-payment, real-time power billing and real-time monitoring.
Functions
Power Measurement function
It can execute time-measuring of assembled active power, positive and negative active power, assembled reactive power, four-quadrant reactive power, positive and negative apparent power, as well as copper loss and iron loss power.
Multi-rate function
It has adopted two sets of rates and time consumption with capacity of free programming, to support setting special rates comsumption for public holidays.
Step tariff function
It has adopted two sets of step tariff billing, and can set the time of implementing the other billing.
Rates control
It has used local (CPU card / RF card), or remote (carrier / RS485) rates control method.
Freeze function
Support four freezing methods, namely timing freezing, instantaneous freezing, agreed freezing and day-time freezing.
Load curve recording
According to users’ settled time, it will execute cycling record about the content of the selected various data in interval. And the data volume can reach that of 40 days within one-minute interval.
Power network monitoring
Provide monitoring function of exceeding limit. It can set limit value of such parameters as wire (phase) voltage, current, power factors, and can also offer monitoring.
Event recording function
Record various events such as loss of voltage, loss of phase failure, power failing, voltage (current) reverse phase sequence, programming, power demands clearing, broadcasting timing, etc.
Alarm function
It will execute sound and light alarm about such events as loss of voltage, loss of current, reverse phase sequence, overload, reverse power, and battery with less voltage.
Cover-opening recording
It can record whether it has opened the meter cover or the terminal cover.
Main technical parameters
Accuracy Class | Active : 0.5S, 0.5, 1 Reactive: 2 |
Reference Voltage Un(V) | Three-phase and four-wire: 3×57.7/100,3×220/380 Three-phase and three-wire: 3×100 |
Operating Voltage | 0.7 Un~ 1.2 Un |
Rated Current Ib(A) | 3×0.3(1.2), 3×1.5(6), 3×3(6), 3×5(6), 3×5(20),3×5(40), 3×10(40),3×10(60),3×15(60),3×20(80) |
Rated Frequency | 50Hz |
Power Consumption | Voltage circuit: ≤ 1.5W,6VA Current circuit: <1VA |
Display Mode | LCD |
Communication Interface | Infrared, the first channel RS485, low-voltage power line carrier |
Overall Dimensions | 290mm´170mm´85mm |
Work Environment | Normal operating temperature: -25°C~+60°C Limit of operating temperature: -40°C~+70°C Storage and transport temperature: -40°C~+70°C Storage and Operating humidity: ≤85% |