One pulse/revolution (ACT-1B) or 60 pulses/revolution (ACT-1B-60) O/P options: 4-20 mA (12 bit), 0-5 Vdc (12 bit) or TTL pulses
Port: Mumbai.
Minimum Order Quantity: 1 Unit/Units
Supply Ability: 200 Unit/Units per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: As per buyer specification
Delivery Detail: 1 week.
Panel Tachometer
Features:
ACT-1B (5-99,999 RPM)
ACT-2A (5-999,990 RPM)
ACT-3 (5-999,990 RPM)
Applications :
Technical Data | ||
Type | ACT-1B | ACT-3X |
Speed Range | 5 to 99,999 RPM | 5 to 999,990 RPM (single pulse per revolution),±0.5 to 999,990 RPM (10 pulses per revolution). Speeds below 5 RPM are possible with multiple pulses per revolution |
Accuracy | ±1 RPM or 0.005% of reading | ±0.001% of reading or ±1 displayed resolution (Standard Gate), ±0.01% of reading or ±1 displayed resolution (Fast Gate). |
Resolution | 1 RPM | Up to 0.001 RPM, 10 RPM (100,000 to 999,990 RPM) |
Display | 5 digit, 0.56 (14 mm) high red LED | 5 digit, 0.56 (14 mm) high red LED |
Display Update | Twice per second above 120 RPM. Programmable with PM Remote Software and USB programming cable. | Menu Selectable between: 0.5 second above 120 RPM, 1 second above 60 RPM and 1.5 seconds above 40 RPM. |
Dimensions | 1/8 DIN by 4.5 (114 mm) deep. Panel cutout: 3.58 x 1.74 (91 x 44mm) | 1/8 DIN by 4.5 (114 mm) deep. Panel cutout: 3.58 x 1.74 (91 x 44mm) |
Input Power | Standard: 100 - 240 Vac ±10%, 50/60 Hz Optional:±12 or 24 Vdc ±10%, Isolated, 6.0 Watts | Standard: 100 - 240 Vac ±10%, 50/60 Hz Optional:±12 or 24 Vdc ±20%, Isolated, 6.0 Watts |
Inputs | Universal input for optical, proximity, two wire or three wire magnetic, infrared or laser sensors. TTL input or 1.5 Vac to 50 Vac input. Standard input is 1 pulse per revolution. | Universal input for optical, proximity, two wire or three wire magnetic, infrared or laser sensors. TTL input or 1.5 Vac to 50 Vac input. Standard input is 1 pulse per revolution. |
Sensor Excitation | 5Vdc or optional 12Vdc or 24Vdc to senso | 5Vdc or optional 12Vdc or 24Vdc to sensor |
Recommended Sensors | Optical - Monarch ROS-W, ROS-P-25, ROS-HT-W-25, ROSM-5W Proximity - Monarch P5-11 Magnetic - Monarch M-190W or MT-190W Infrared - Monarch IRS-W Laser - Monarch ROLS-W, SLS-115/230 Inductive - Gas Engine GE-200 | Optical - Monarch ROS-W, ROS-P-25, ROS-HT-W-25, ROSM-5W Proximity - Monarch P5-11 Magnetic - Monarch M-190W or MT-190W Infrared - Monarch IRS-W Laser - Monarch ROLS-W, SLS-115/230 Inductive - Gas Engine GE-200 |
Analog Output (Optional) | VOLTAGE (AO): 0 to 5 Vdc out, 5 mA 16 bit resolution. Full scale RPM settings as specified when ordered or programmable using PM Remote Software and USB programming cable. or CURRENT (IO): 4 to 20 mA out, 16 bit resolution 12Vdc compliance voltage. Full scale RPM settings as specified when ordered or programmable using PM Remote Software and USB programming cable. | Voltage (AO): 0 to 5 Vdc, 5mA max load (isoloated or non-isolated) or Current (IO): 4 to 20mA, 500Ω max load. (isolated or non-isolated), 1 to 5Vdc possible using 250Ω resistor) 16 bit resolution. Front panel push button programmable for full scale and offset RPM ranges. |
Pulse Output | 0 to 5 V TTL pulse, non-inverting, one pulse out for each pulse in. Positive or negative out. Programmable using PM Remote Software and USB programming cable. | Standard, 0 to 5 V TTL compatible. One pulse out for each pulse in. Menu selectable polarity |
Remote Programming | Unit can be remotely programmed using optional communications interface cable and PM Remote Software. | Unit can be remotely programmed using optional communications interface and PM Remote Software. |
Environmental | Indoor use only, Installation category II per IEC 664 Temperature: -10ËšC to 50ËšC operating per IEC 61010-1 Humidity: Maximum relative humidity 80% for temperatures up to 31ËšC, decreasing linearly to 50% relative humidity at 40C | Indoor use only, Installation category II per IEC 664 Temperature: -10ËšC to 50ËšC operating per IEC 61010-1 Humidity: Maximum relative humidity 80% for temperatures up to 31ËšC, decreasing linearly to 50% relative humidity at 40C |
Electrical Safety | Meets EN61010-1:2001, EC low voltage directive 72/23/EEC and 89/336/EEC | Meets EN61010-1:2001, EC low voltage directive 72/23/EEC and 89/336/EEC |