1. RLC precision load, 2. Intelligent control, 3. Anti-Islanding Test Device, 4. Satisfy 2KW inverter anti-islanding testing - more info check here: http://www.buymeasuringtools.com/PV-Inverter-Anti-Islanding-Testing-RLC-Load-Bank-ACLT-2202H-10211951/

Quick Brief

Place of Origin: Jiangsu China (Mainland) Brand Name: INNET Model Number: ACLT Power: Satisfy 2KW grid inverter and below anti... Usage: PV Inverter Islanding Prevention Detecti... RLC load: Grid-Inverter Anti-Islanding Detectio...

Product Features:

1. RLC precision load

2. Intelligent control

3. Anti-Islanding Test Device

4. Satisfy 2KW inverter anti-islanding testing

Business Terms:

Port: Tianjin

Minimum Order Quantity: 1 Set/Sets

Payment Terms: L/C,T/T

Contact Supplier
PV Inverter Anti-Islanding Testing RLC Load Bank ACLT-2202H
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: wooden case

Delivery Detail: 30-45 days after PO confirmed

Specifications and Product Details:

ACLT-2202H: PV Inverter Anti-Islanding Testing RLC Load Bank

UL Germany, Intertek Guangzhou and Shanghai, TUV Rheinland Taiwan and Shanghai, TUV SUD Guangzhou and Wuxi and BV are our customers.

Satisfy 2000W and below grid Micro-Inverter anti-islanding test

Input Voltage: AC230V50Hz, AC240V60Hz, AC120V60Hz

Anti-Islanding Test Device satisfies the testing of grid inverter requirements. It satisfies IslandingPrevention Detection of utility grid inverter, work efficiency test of utility grid inverter, overload protection test, over-current protection test, power factor experiment, grid electric current harmonic test and so on.

Built-in precision load. The major loop is consisted of resistive load, inductive load and capacitive load.

It satisfies grid micro-inverter testing.

RLC load control mode: remote PC control.

The three parts of load is controlled by switches piecewise, can be adjusted automatic or manual

Resistive load R: 0-2000W, adjustable continuously, total power 2.11KW

Inductive load L: 0-2000VA, adjustable continuously, total power 2.11KW.

Capacitive load C: 0-2000Var, adjustable continuously, total power 2.11KW

The maximum power under kinds of input voltage and frequency as follows:

AC 230V/50Hz,RLC each 2.11KW;

AC 240V/60Hz, R 2.297KW L 1.915KW C 2.757KW;

AC 120V/60Hz, R 0.574KW L 0.478KW C 0.68KW;

Resistive part, Inductive part and capacitive part could be combined wilfully, the minimum stepping amplitude is 0.001K.

The power of resistive load, inductive load and capacitive load could be independent controlled and adjusted, it satisfies that adjust the resonant point accurately when the voltage was unbalance. It satisfies the testing needs of grid inverter full load, it simulates the occurrence of the circuit resonance accurately; effectively inspect the Islanding Prevention function of utility grid inverter.

Precision of voltage is ±0.5%, resolution of voltage is 0.1V; current measurement range 0-30A; precision of current is ±0.5A.

The range of applicable environmental temperature:-10 ~ +40°C; Type of cooling: forced air cooling;

The way of connection: Single-phase two wire.

It satisfies the requirements of test of the grid inverter anti-islanding experiment, it satisfies the requirement of test of IEC62116-2008 standard experiment, and version IEC62116-2008 has internal test steps (31 times)

PV Inverter Anti-Islanding Testing RLC Load Bank ACLT-2202H suppliers    PV Inverter Anti-Islanding Testing RLC Load Bank ACLT-2202H manufacturers