Home  >  Flow Measuring Instruments  >  Flow Meters

PTFE/Rubber insertion type electromagnetic flow meter - LD

PTFE elemagnetic flow meter, 1)without pressure loss, 2)can be with high pressure, 3)Hart or profibus commucation - more info check here: http://www.buymeasuringtools.com/PTFE-Rubber-insertion-type-electromagnetic-flow-meter-10312357/

Quick Brief

Place of Origin: Anhui China (Mainland) Brand Name: Tianwei Model Number: LD Body Material: Carbon Steel Lining Material: Rubber,PTFE Power supply: 220VAC,24VDC or battery Electrode: HC,HB,316LSS,Ti,Tan,Pt Structure: Integral or Remote

Product Features:

PTFE elemagnetic flow meter

1)without pressure loss

2)can be with high pressure

3)Hart or profibus commucation

Business Terms:

Port: Hefei China

Minimum Order Quantity: 1 Set/Sets depends on your requirment

Supply Ability: 3000 Set/Sets per Month earlier

Payment Terms: L/C,T/T,Western Union

Contact Supplier
PTFE/Rubber insertion type electromagnetic flow meter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: export packing,carton

Delivery Detail: 2~10days

Specifications and Product Details:

PTFE electromagnetic flow meter
Specifications

1>electromagnetic flowmeter, electromagnetic flow meter
2>flange,triclover,clamp,thread connection,etc
3>4-20mA,pulse,HART,485

electromagnetic flowmeter is an inductive apparatus to measure the flow volume of electric medium in the tube.The flowmeter composes of sensor and converter.The electromagnetic flowmeter can not only be read straightly but also output 4-20mA current signal for purpose of memory,adjustment and control,It is extensively used in industry technology and administration department such as chemical industry,environmental protection,medicine,paper making and water supply ,etc.

Technical Features:

  • Not affected by the change of the fluid condition such as density, viscosity, temperature, pressure and conductivity, and the signal output of inductive voltage is linear to average velocity, therefore it has a high accuracy of measurement.
  • No obstacle parts in the meter tube so that no extra pressure loss; no movable parts, so meter has long service life.
  • Short straight pipe required, only 5D for upstream and 3D for downstream due to inductive voltage signal which is the average value in the cross-section of the pipe.
  • Only liner and electrode contact to the fluids, choose proper material of liner and electrode to prevent it from corrosion to ensure meter long operation life.
  • MCU and SMT technology used in converter to make it has high performance, high accuracy, low power consumption, stable zero point, easy parameter setting, dot-matrix display for total and instantaneous flowrate, velocity and percentage of flowrate.
  • Two-direction measurement for forward and reverse.

Technical Specifications:

  • Size: DN 10 ~ DN 2000
  • Medium: Conductive liquid, slurry
  • Medium Temperature: E grade∠60oC, H grade∠180oC
  • Conductivity: ≥ 5 μS/cm
  • Accuracy: ±0.5%, ±1.0%
  • Repeatability: ±0.1%
  • Rated Pressure: 0.25, 0.6, 1.0, 1.6, 4.0MPa (or specified by customer)
  • Display: Instantaneous flowrate, total flow, velocity, flowrate percentage with back light
  • Signal Output: 4~20mA current output, pulse output, RS-485, Hart, Profibus-DP
  • Power Supply: 220VAC, 24VDC
  • Converter Type: Compact, remote
  • Protection Grade: IP67/ IP68
  • Explosion Proof: Ex deibmb IIC T3~6
  • Velocity: 0.3 ~ 12m/s( 0.1 ~ 15m/s as required)
  • Liner: Chloroprene Gum (DN50 ~ DN3200) / Polyurethane (DN25 ~ DN500) / F4 (PTFE) (DN25 ~ DN1600) / F46 (FEP) (DN10~DN200) / PFA (DN10~300)
  • Flowing Direction: Forward, Reverse
  • Electrode Material: 316L, Pt, Ta, Ti, HB, HC, WC
  • Electrode Type: Standard fixed type, blade type
  • Electrode Number: 4 ~ 6 pcs
  • Flange Material: SS / CS
  • Alarm (normal open): Empty, excitation, upper / lower limit
  • Ambient: Temperature: -25 ~ +60oC, Humidity: 5 ~ 90%
  • Communication: RS-485 / Hart / Profibus-DP

Pparatus selection
DNUsual full range flow volume selection(m3/h)IntegrationPartial installation
weights(KG)weights (KG)
100.16,0.2,0.25,0.3,0.4,0.5,0.6,0.8,1.0,1.2,1.6,2.0,2.564
150.4,0.5,0.6,0.8,1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.064
200.6,0.8,1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.064
251.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.075
321.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.097
402.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0108
504.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,701210
65,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,80,100,1201715
8010.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,80,100,120,1601715
10016.0,20.0,25.0,30.0,40.0,50,60,80,100,120,160,200,2502220
12525.0,30.0,40.0,50,60,80,100,120,160,200,250,300,4002422
15040.0,50,60,80,100,120,160,200,250,300,400,500,6003533
20060,80,100,120,160,200,250,300,400,500,600,800,10004543
250100,120,160,200,250,300,400,500,600,800,1000,1200;16008482
300120,160,200,250,300,400,500,600,800,1000,1200;1600,2000,2500102100
350200,250,300,400,500,600,800,1000,1200;1600,2000,2500,3000123121
400250,300,400,500,600,800,1000,1200;1600,2000,2500,3000,4000147145
450300,400,500,600,800,1000,1200;1600,2000,2500,3000,4000,5000212210
500400,500,600,800,1000,1200;1600,2000,2500,3000,4000,5000,6000229207
600600,800,1000,1200;1600,2000,2500,3000,4000,5000,6000,10000252250
700800,1000,1200;1600,2000,2500,3000,4000,5000,6000,10000,12000352350
8001000,1200;1600,2000,2500,3000,4000,5000,6000,10000,12000,16000462460
9001200;1600,2000,2500,3000,4000,5000,6000,8000,10000,12000,16000550
10001600,2000,2500,3000,4000,5000,6000,8000,10000,12000,16000;20000680

PTFE/Rubber insertion type electromagnetic flow meter suppliers    PTFE/Rubber insertion type electromagnetic flow meter manufacturers