1.Range:0~150MPa
2.Power:85~265VAC
3.Output:0~10V,4~20mA etc.
4.Alarm:2 relay alarm
5.CE certificate
Port: ChengDu
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 1000 Set/Sets per Month
Payment Terms: T/T,Western Union,MoneyGram,paypal
Contact Supplier
PS1016T Series Pressure And Temperature Indicator
Introduction
PS1016T series pressure and temeprature indicator is developed on the besis of PS1016 series added the temperature measurement and display function to realize one pressure indicator double functions.It is widely used in oil fibers,plastic and rubber for industry high temperature melt pressure and temperature's measurement and control.
Performance
1. Automatic calibration function;
2. Panel error correction function;
3. Four digital displays with two layers and double colors;
4. Using a variety of alarm mode;
5. Providing single and double line output;
6. Providing variety of voltage or current linear output signal;
7. Providing RS485 computer communication interface;
8. Compatible with a variety of pressure input signal;
9. Triple anti-jamming technology;
10. More than 20000 hours trouble-free operation;
11. Providing the pressure and temperature dual measurement and dual display function, supporting the thermocouple of E, J, K type and thermal resistance of Pt100 RTD input.
Specifications
Order Format
Example1: PS1016T-035-206-311-6J
Product Model "PS1016T",Pressure&Temperature Indicator.
Pressure Range Code "035",The pressure range is 0~35Mpa;
Output Signal Code "206", The factory setting output signal is 0 ~ 10V;
Alarm Code "311",The factory setting adopts 2-way relay top and bottom limitation alarm;
Temperature configuration"6J",J type thermocouple.
Vacancies and not marked function codes are the default values.
Example2: PS4812-050-124-205-311-433-5H-6J-7R
Product Model "PS1016T" ,Pressure&Temperature Indicator.
Pressure Range Code "050",The pressure range is 0~50MPa
Power Code "124", The supply power is 24V DC;
Output Signal Code "205", The factory setting output signal 4~20mA;
Alarm Code "311",The factory setting adopts 2-way relay top and bottom limitation alarm;
Input Signal Code "433",It is mating for the transducer that has 3.33mV/V output;
Shape Code "5H",The dimension is 96*48mm;
Temperature configuration"6J",J type thermocouple;