Fatigue test lab equipment
1.test fatigue lifetime of all kind of part
2.bending,torsion fatigue test machine
3.precision 1%
Port: qingdao
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 300 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: wooden case
Delivery Detail: within 15 days after the payment
PLG Computer Control Resonant High Frequency Fatigue test Lab Equipment
Application
Electromagnetic resonance High-frequency fatigue testing machine has simple structure, convenient operation, high efficiency, low energy consumption and other characteristics, therefore it widely is used in the field of military scientific research, colleges and universities and industrial production.High-frequency fatigue testing machine is widely used for testing properties of anti-fatigue crack, testing KIC value, S-N curve and so on; it is used for testing fatigue lifetime of all kinds of parts (e.g. plate gear, crank, bolt, chain, connecting rod, compact tension and so on) with various fixtures. It may complete the symmetrical fatigue test, the asymmetrical fatigue test, the unidirectional pulsation fatigue test, the block spectrum fatigue test, the modulation fatigue test, the fatigue test at high and low temperature, three point bending, four point bending, torsion fatigue tests and so on. At present colleges and universities, research department and industrial and mining enterprises use the high frequency testing machine to carry on fracture toughness test and testing metallic material crack growth rate and limited value of martial. With the development of microelectronic technology and computer technology, as well as perfect test method, its use function is increasing expansion.
Specifications
Model | PLG-10C | PLG-20C | PLG-50C | PLG-100C | PLG-200C | PLG-300C | ||
Mean load max(kN) | ±10 | ±20 | ±50 | ±100 | ±200 | ±300 | ||
Force amplitude(kN) | ±10 | ±10 | ±10 | ±50 | ±100 | ±150 | ||
Load step | 1,2,5 | 1,2,5 | 1,2,5 | 1,2,5 | 1,2,5, | 1,2,5 | ||
Accuracy of static load | ≤±1% | |||||||
Range of frequency(Hz) | 60~300HZ | |||||||
Power | 380V, 3phs, | |||||||
Load fluctuation | Dynamic | 0.5%F-S | ||||||
Static | 0.5%F-S | |||||||
Max. distance between grips (mm) | 600 | 600 | 600 | 800 | 800 | 800 | ||
Max. distance between columns (mm) | 400 | 420 | 480 | 500 | 540 | 620 | ||
Dimension (mm) | Main unit | 680×500 ×1900 | 700×500 | 800×700 ×2235 | 900×800 ×2600 | 1100×1100 | ||
Electric controller case | 600×650×1200 | |||||||
weight (kg) | Main unit | 1300 | 1500 | 1500 | 2750 | 4000 | 7200 | |
Electric controller case | 50 | 50 | 70 | 70 | 100 | 120 | ||
Working mode
Conventional fatigue test is the constant dynamic and static load (symmetrical, asymmetrical, pulsation), program control (block spectrum) fatigue test and modulation fatigue test (sine wave, triangular wave, trapezoidal wave, self-defining wave and so on).
Capacity of counter is 9 109.
The testing machine can automatically record testing cycle number, and cycle number can be established at any time. After arriving at the stipulation cycle number, the testing machine has the auto-stop function.
Data storage method
Equal time interval storage and equal number storage;
Waveform display functions
Real time display waveform has dynamic load waveform, current waveform and excitation waveform, and it mainly is used for diagnosing resonant condition.
Protection Safety
It has overload protection, mechanical limit protection, over current of motor protection, fracture protection, actuator overflow protection, frequency falling protection, contrived upper and lower limit of dynamic and static load protection, out of control dynamic and static load protection and so on. Frequency falling protection and upper and lower limit of dynamic and static load protection can be contrived according to different experimental requirements. The basic condition of equipment use
Field environmental condition
Environmental temperature range is (-10~+40)°C.
Environmental relative humidity is less than 80%.
Altitude is no more than 1000m.