PHB-4 Portable pH Meter
1.Auto-correction, auto-temperature compensation.
2.LCD,displaying pH and temperature simultaneously
PHB-4 Portable pH Meter
Features
1. LCD, displaying pH and temperature simultaneously.
2. Automatic correction, automatic temperature compensation.
3. There are 2 series of pH standard buffer solutions for choice: China series and Europe series.
4. Temperature units: °C or °F.
5. Low voltage display, auto-power off in 15min.
Specifications.
pH | Measurement Range | (0~14.00)pH |
Resolving Capability | 0.01pH | |
Accuracy | Meter: ≤±0.01pH ±1byte Kit: ≤±0.02pH ±1byte | |
Temperature Compensation | (0~80) °C (Automatic) | |
mV | Measurement Range | ±1999mV |
Resolving Capability | 1mV | |
Accuracy | ≤±0.1%FS ±1byte | |
Other Parameters | Input Impedance | ≥1×1012Ω |
Power | 6F22/ 9V laminate cell | |
Dimension & Weight | (168×43×26)mm/ 170g | |
Operating Condition | Ambient Temperature | (5~35)°C |
Relative Humidity | ≤85%RH |
Characteristics
A portable pH meter with automatic temperature compensation can be used in the field.
Package includes
No. | Name | Quantity |
1 | PHB-4 Portable pH Meter | 1 |
2 | 201B-S Plastic pH/ATC Trinal Combination Electrode | 1 |
3 | pH 4.00, 6.86, 9.18 Buffer Solutions (50mL) | 1 Bottle for Each |
4 | 6F22/ 9V Laminate Cell | 1 |
5 | Meter Hand Case | 1 |
6 | Instruction Book | 1 |
7 | Certificate | 1 |
Optional Accessories
Category | Name | Basic Features and Specifications |
pH Combination Electrode | 201-A Plastic pH Combination Electrode | For conventional pH measurement; electrode extension cord is configurable; BNC plug. |
201-C Plastic pH Combination Electrode | For convention pH measurement; with wide application; BNC plug. | |
200-C Plastic pH Combination Electrode | For convention pH measurement; high accuracy for long testing period; BNC plug. | |
206-C Plastic pH Combination Electrode | The outside diameter of electrode is small, suited to be used in test tubes or containers with small diameter; BNC plug. | |
2015P-C Plane Plastic pH Combination Electrode | For surface pH measurement, and pH measurement with a trace of solutions; BNC plug. | |
Electrode Extension Cord | Adapt to 201-A electrode. | |
ORP Combination Electrode | 301Pt-C Plastic ORP Combination Electrode | For conventional ORP measurement; BNC plug. |
pH Calibration Buffer Solution | pH4.00 Calibration Buffer Solution | 500mL/250mL/50mL (Bottle) |
pH6.86 Calibration Buffer Solution | ||
pH7.00 Calibration Buffer Solution | ||
pH9.18 Calibration Buffer Solution | ||
pH10.01 Calibration Buffer Solution | ||
Electrode Filling Solution | pH(ORP) Combination Electrode Filling Solution | 500mL/250mL/50mL (Bottle) |
ORP Standard Reagent | 260mV ORP Standard Reagent | 50mL/Pack |
ORP Standard Reagent | 222mV ORP Standard Reagent | 250mL/100mL/50mL (Bottle) |