Infrared gas leak detector:
1.detect gases include C2H2, CH4, C4H10, C2H4, C2H6, C3H8, CO2,CO and SF6, etc.
2.Good stability
Port: Zhengzhou
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 50 Unit/Units per Week
Payment Terms: T/T
Contact SupplierPackaging Detail: Customary Packing and Oringinal Packing is available.
Delivery Detail: 5 days
PGas-31 Infrared Gas Detector
The measurement principle of (NDIR) "Non-dispersive Dual-wavelength Infrared Spectrum" is adopted for PGas-31 gas infrared quantitative detector. There is no radiotive emitter and it is convenient to carry; the screen of hand-held probe uses OLED, it is self-luminous with high brightness, with no visual angle problem; high precision, good stability and sensitivity, and the resolution of leakage detection can reach 0.1ppm; the response time is fast; with no consumable parts, life time of the sensor is extra long; it can detect gases include C2H2,CH4,C4H10,C2H4,C2H6, C3H8,CO2,CO and SF6, etc.
PGas-31 gas infrared quantitative detector is mainly composed of two parts: the host machine and hand-held probe.
1.Display screen of host machine
2. Host machine
3. Power switch
4. Aviation plug
5. Filter cap
6. Probe rod
7. Probe panel
8. Probe
9. Communication wire
Hand-held probe is embedded with microcontroller, besides the function of gas sampling, detecting and displaying the concentration of gas, the controller also have functions of calibration, alarm value setting and acoustooptic alarm, etc., the operation is simple and the using is convenient. The hand-held probe is connected with the host machine through a cable to transfer the data.
Host machine besides power supply to the hand-held probe, the host machine can also receive the measurement data transmitted from the hand-held probe, so as to perform display and storage, meanwhile, it can also realize the functions of alarm setting, storage mode setting and display mode setting, etc., the operation is simple and the using is convenient. When the concentration exceeds the alarm value, the detector shall issue alarm signal, prompting gas leakage, and reminding people of adopting measures early.
Main features
The probe unit adopts light-emitting display screen of organic matter, it is self-luminous with low power consumption and high brightness, and there is no problem of visual angle
The host machine adopts 3.5 inch color touch display screen, the brightness is high, the visual angle is small and the contrast is adjustable
The sensitivity is high, the detection of leakage can reach 0.1 ppm, and the precision can reach 1ppm at most
Good stability
Swift response time
Acoustoptic alarm
Facilitates carrying;
It can realize manual storage of measurement data;
Long service life of sensor
Technical parameters
Parameter | Characteristics |
Measurement principle | Infrared (NDIR) |
Measurement range | Refer to lectotype table |
Sampling mode | Pumping type |
Service temperature | -10~60°C |
Power supply | 7.2V DC, internal battery power supply |
Response time (T90s) | 1~5 second(s) |
Warm-up time | 100 seconds |
Probe unit rod length | 22cm |
Service life of sensor | >10 years |
Calibration time | Calibration once every six months |
Alarm mode | Buzzer |