1.surface is smooth and beautiful
2.water-proof design
3. high precision and stability
4.small size, light weight
Port: shanghai
Minimum Order Quantity: 1 Set/Sets Carton/Cartons
Supply Ability: 100 Set/Sets per Week Month
Payment Terms: T/T
Contact SupplierPackaging Detail: carton/cartons
Delivery Detail: one week~one month
<1>Smith 2014-oval gear flow meter is a volume measuring instruments, measured mainly by Shell, the oval gear transmission and rotor components. It is using in the pipeline for continuous or intermittent liquid flow measurement and control instrumentation. It has wide range, excellent accuracy, small pressure loss, viscosity strong adaptability and high viscosity liquids capable of measuring temperature calibration convenient, simple to install, and other advantages. Apply to crude oil, chemicals, chemical fiber, traffic, commerce, food, medicine and health care, scientific research and military industries in the flow measurement. SMITH2014 oval gear flow meter can be directing the cumulative flow, instantaneous flow, a single flow, and so on, can also be output pulse signal, 4-20mA, or 1-5 V analog signals 4-20mA +HART, MODBUS, communications and other support 232,485. Smith and mechanical or electronic controller grant awarded controller combinations can be realized for different types of filling, control, and other functions approved.
<2>Technology Indicators
Allow basic error: ± 0.2% ± 0.5%
Nominal Path DN (mm): 4 ~ 300
Nominal pressure PN (MPa): stainless steel 1.0, 1.6,2.5,4.0,6.3
Carbon Steel 2.5,4.0, 6.3, 9.6
Measured the temperature of the liquid: -40°C ~+60°C, -30°C ~ +80°C
+60°C~ +200°C, +100°C~ +300°C
Tested the liquid viscosity(mPa.s): 0.3 ~ 50000
Pipeline Connection: GB/T9118-2000 (China flange); NIST (USA standard flange); BSPT (British Standard Pipe Thread); NPT (the United States pushed and pulled out thread);
Field Show: 999999999 (cumulative flow) 99999999.9 (single flow)
9999999.9 (instantaneous flow)
Output signal: pulse signals, 4 ~ 20mA, 1-5V, 4 ~ 20mA +HART agreement, MODBUS Support RS232, RS485 communications (optional)
Ex Rating: ExdIIBT5 ExiaIICT5
Protection Level: IP65 IP67
<3>Flow meter basic specifications, flow and viscosity Table
Basic Model | Nominal Path(mm) | 0.5-1.5 | 1.5-10 | 10-150 | 150-350 | |||||
Smith14/10 | 10 | Max Min | 0.4 0.8 | 0.4 0.16 | 0.4 0.065 | 0.4 0.13 | 0.3 0.05 | 0.3 0.065 | 0.27 0.04 | 0.27 0.068 |
Smith14/15 | 15 | Max Min | 1.8 0.38 | 1.8 0.76 | 1.8 0.26 | 1.8 0.52 | 1.6 0.26 | 1.6 0.32 | 1.35 0.22 | 1.35 0.33 |
Smith14/20 | 20 | Max Min | 4 0.55 | 4 1.1 | 4 0.4 | 4 0.8 | 3.5 0.4 | 3.5 0.5 | 2.8 0.35 | 2.8 0.55 |
Smith14/25 | 25 | Max Min | 8 1 | 8 2 | 8 0.8 | 8 1.6 | 7 0.8 | 7 1.0 | 5.6 0.7 | 5.6 1.1 |
Smith14/40 | 40 | Max Min | 20 2.4 | 20 4.8 | 20 2 | 20 4 | 18 2 | 18 2.2 | 15 1.7 | 15 3 |
Smith14/50 | 50 | Max Min | 30 3.6 | 30 7.2 | 30 3 | 30 6 | 27 3 | 27 4 | 22 2.5 | 22 4.8 |
Smith14/80 | 80 | Max Min | 60 7 | 60 14 | 60 6 | 60 12 | 54 6 | 54 10 | 35 4 | 35 7 |
Smith14S/80 Smith14/100 | 100 | Max Min | 100 12 | 100 24 | 100 10 | 100 20 | 90 10 | 90 11 | 80 8 | 80 12 |
Smith14S/100 Smith14/150 | 150 | Max Min | 190 23 | 190 46 | 190 19 | 190 38 | 175 19 | 175 30 | 160 17 | 160 23 |
Smith14/200 | 200 | Max Min | 340 40 | 340 80 | 340 34 | 340 68 | 320 34 | 320 56 | 280 30 | 280 40 |
Smith14/250 | 250 | Max Min | 540 60 | 540 120 | 540 54 | 540 108 | 500 54 | 500 78 | 420 45 | 420 60 |
Smith14/300 | 300 | Max Min | 720 80 | 720 160 | 720 72 | 720 144 | 670 72 | 670 92 | 560 62 | 560 80 |
Accuracy level | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 |