Home  >  Electrical Instruments  >  Energy Meters

Network power meter(ACR330EGH) - ACR330EGH

3P3L, 3P4L, Frequency 45~65Hz, Voltage Normal: AC 100V, 400V, High quality - more info check here: http://www.buymeasuringtools.com/Network-power-meter-ACR330EGH-10047061/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: ACREL Model Number: ACR330EGH Display Type: Digital Only Accuracy Class: Frequency 0.01Hz, reactive ener... Output Voltage: Mode: 4 NO contacts (AC 250V/3A... Operating Temperature: Working T: -10℃~+45℃; St... Network power meter: energy meter

Product Features:

3P3L, 3P4L

Frequency 45~65Hz

Voltage Normal: AC 100V, 400V

High quality

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 10000 Piece/Pieces per Year

Payment Terms: L/C

Contact Supplier
Network power meter(ACR330EGH)
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: packed by case

Delivery Detail: within 2 weeks

Specifications and Product Details:

1. General

ACR330EGH is a kind of electrical network analyzer designed by ACREL under the IEC norm, and it has several international advanced technologies.

It can measure all the electrical data in the three phase network, including measurement of multi-rate energy and 4-quadrant energies, harmonic and quality of electrical network analysis, 4 logic inputs, 3 relay outputs and RS485 communication. Therefore ACR330EGH can be widely used in SCADA and DCS system.

2. Characteristics
1, Measuring accurately the data of three phase network, such as phase voltages, line voltages, current, active, reactive and apparent power, power factor etc..;

2, 4-quadrant energies, including active capacitive energy, active inductive energy, reactive capacitive energy and reactive inductive energy; It can also count the energies in 8 zone times by 3 tariffs (the energies in this month, in last month, in before last month and total energy);

3, Measuring component and THD of the 2~31 ranges harmonic of current and voltage, current K-factor, voltage crest factor, waveform factor, degree of voltage and current unbalance etc.., and users can analyze the electrical network quality with these data;

4, It can be equipped 4 logic inputs, 3 relay outputs, 1 RS485 communication with MODBUS protocol in order to satisfy the demand of measurement and control in long distance.

3. Technical features

Feature

Values

Input

NetworkSingle phase, 3P3L, 3P4L
Frequency45~65Hz

Voltage

Normal: AC 100V, 400V
Overloading: 600V(continuous); 1000V / 30s
Consumption: < 0.2VA

Current

Normal: AC 1A, 5A
Overloading: 6A(continuous); 50A /1s
Consumption: < 0.2VA

Pulse output

Mode: Optocoupler pulse output

Communication

RS485 (Modbus-RTU)

Logic input (DI)

4 drying contact inputs, with +5V power

Logic output (DO)

Mode: 4 NO contacts (AC 250V/3A, DC 30V/3A)

Accuracy

Frequency 0.01Hz, reactive energy 1 class, others 0.5 class

Display

LCD

Power supply

AC/DC 85~270V; consumation: ≤4VA

Isolation

Power / current input / voltage input: AC2kV/1min;

Power / logic inputs / RS485: AC1.5kV/1min;

Inputs / outputs / housing >5MΩ

Environment

Working T: -10°C~+45°C; Storing T: -20°C~+70°C Relative humidity: 5%~95% Non-Condensing; Altitude: ≤2500m
Network power meter(ACR330EGH) suppliers    Network power meter(ACR330EGH) manufacturers