Quick Brief

Place of Origin: Zhejiang China (Mainland) Brand Name: Nade-Spectrophotometer Model Number: F96PRO Size: 550x510x365(mm) Weight: 13kg Wavelength Range: 250-700 nm Measurement Range: 250-700 nm Wavelength: 250-700 nm Linear measurement(r): ≥0.995

Product Features:

1.Two operation mode could be chosen

2.365nm exciting wavelength

3.10 stages gain adjustment

4.Support off-line mode&on-line

Business Terms:

Port: Shanghai, Hangzhou

Minimum Order Quantity: 1 Set/Sets courier suggested

Supply Ability: 20 Set/Sets per Month all kinds of spare parts

Payment Terms: L/C,T/T

Contact Supplier
Nade Fluorescence spectrophotometer F96PRO
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: standard packing for export

Delivery Detail: 15-20 days after payment

Specifications and Product Details:

Features

* Two operation mode could be chosen: fluorescence intensity and luminous intensity. Fluorescence scanning,

kinetic determination and quantity analysis could be done under fluorescence intensity mode.

* 365nm exciting wavelength Raman peak of water in 1 cm quartz fluorescence cuvette S/N150

High performance sensitivity simplifies the measurement of low detective sample.

* 10 stages gain adjustment could be chosen for emission spectrum scanning, including high speed low S/N

scanning and precise scanning. Total spectrum scanning could be done in 1 second. With the intelligent pre

scanning feature, unknown sample's spectrum information could be detected rapidly. Auto- omission of the influence of scattering peak and harmonic peaks, it ensure the best measurement parameters

and locate the fluorescence emission peak.

* Support off-line mode and on-line mode. Under off- line mode, instrument's computer system offer the fluorescence intensity measurement, concentration direct

reading, auto 0 adjustment, auto background subtraction and etc. Under on-line mode, we could use quality and quantity software to control data acquisition and analysis through USB2.0interface.

*High stable and long life 150W xenon lamp and power source ensure high stable testing and wide range of spectrum.

* The normalized feature for fluorescence value could make different fluorescence's result comparable.

* Provide optional PC qualitative and quantitative software package with expansible time scanning, wavelength

scanning, graphic calculation and storage-access abilities.

* Optional accessories for different measurement, including single hole cell holder, fluorescence sample holder

for different features, 200μl micro scale centrifuge tube, micro scale capillary sample holder, semi-auto sample introduction accessories, membrane sample accessories, powder sample accessories,

Applications :

Fluorescence analysis is a high sensitive and high selective sophisticated analytical method. This method can

provide information including excitation and emission spectrum, emission light intensity and measurement of life

of emission light and polarization fluorescence etc. This method can provide a wide lineal range of working curve.

It has becoming an important analytical method in the region of trace analysis. This method has been used in:

1. Medical science and clinical analysis Clinical analysis of biological specimen.

2. Pharmaceutical science and pharmacology Analysis of natural pharmaceutical products; Quality control of

pharmaceuticals and research of pharmaceutical metabolites.

3.Biochemistry Analysis of minute quantity of substances in biological body.

4.Food industry Analysis of minute quantity of constituents in food.

5. Pollution analysis Atmospheric pollution, environmental testing and food contamination analysis.

6. Organic and inorganic chemistry

Specification:

1. Light source:Hamamatsu 150W Xenon lamp

2.Exciting optical filters:Interference optical filter

*Standard set is equipped with an interference optical filter of central wavelength at 365nm and 10nm bandwidth

*An optional interference optical filer of 25mm diameter of wavelength of 250-

700 nm can be provided on users demand.

1. Emission monochromator:C-T diffraction grating(Em 200~900nm,bandwidth 10nm)Wavelength accuracy±1nm Wavelength repeatability ≤0.5nm

2. Sensitivity:Raman peak of water in 1 cm quartz fluorescence cuvette withS/N≥150

3. Linear measurement(r):≥0.995

4. Stability: better than 1.5%/10min

5. Variation of power source:220V±22V 50Hz±1Hz

6. Response time: (0.1-4)s 6 stages adjustable

7. Fluorescence display value: 0.00-600.00

10. Data transmission: USB2.0

Standard Package

Main instrument1 set
365nm filter(Preassembled)1 pc
F96PRO software package1 set
Power cable1 pc
USB wire1 pc
Instruction manual1 copy
Product quality certificate1 copy
Fuse(2A)2 pcs
Fuse(5A)2 pcs
Quartz fluorescence sample cell10mm1 pair
Packing list1 copy

Nade Fluorescence spectrophotometer F96PRO suppliers    Nade Fluorescence spectrophotometer F96PRO manufacturers