Multifunction process calibrator YH7031 Equivalent to Fluke 725
1)Loop Power Voltage: 24V
2)Maximum Current: 24 mA,
3)OEM
Port: Shenzhen Port
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 10000 Piece/Pieces per Month More can be provided according to customers' need
Payment Terms: T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: carton box for outer ,gift box for unit
Delivery Detail: 5-7 days usually
Function | Measure Singal | Measure Accuracy | Output |
DC Voltage | 0.000—30.000 V | 0.02%+3 counts (The upper display) | |
0.000—24.000 V | 0.02%+ 3 counts (The lower display) | ||
0.000—90.000 mV | 0.01%+ 10 counts | ||
-10.000 —80.000mV 0.01 % + 10 counts (use the thermocouple jack ) | |||
DC Current | 0.000—24.000 mA | 0.02%+ 4 counts(The upper display) | |
0.000—24.000 mA | 0.02%+ 4 counts(The lower display) | ||
Resistance | 0.00— 400.00Ω | 0.1Ω (4 wire), 0.15Ω (2 wire and 3 wire) | |
400.0—4000.0Ω | 0.5Ω (4 wire), 1Ω (2 wire and 3 wire) | ||
Frequency | 0.010—20.000 kHz | ±4Hz | |
0.001—39.999.0Hz | ±0.01Hz | ||
40.00 —99.99 Hz | ±0.05Hz | ||
100.0 —500.0 Hz | ±0.5Hz | ||
Pressure | Depends on the pressure module | Depends on the pressure module |
Output | Range | Accuracy | |
DC Voltage | 0.000— 20.000 V | 0.02%+3 counts | |
0.000—90.000 m V | 0.01%+10 counts | ||
-10.000 mV— 80.000 mV 0.01 % + 10 counts (use the thermocouple jack ) | |||
DC Current | 0.000—24.000 mA | 0.02%+ 4 counts | |
Resistance | 5.00 — 400.00 Ω | 0.15 Ω (Excitation current 0.15 to 0.5 mA), 0.1Ω (Excitation current 0.5 to 2 mA) | |
400.0 —4000.0 Ω | 0.5Ω(Excitation current 0.05 to 0.8 mA) | ||
Frequency | 0.040—2.000 kHz | ±2Hz | |
2.000—4.000 kHz | ±8Hz | ||
4.000—8.000 kHz | ±32Hz | ||
8.000—10.000KHz | ±50Hz | ||
Output Hz | 0.030—99.999Hz | ±0.005Hz | |
Pressure | Depends on the pressure module | Depends on the pressure module |
Loop Power Voltage: 24V
Accuracy: 10%
Maximum Current: 24 mA, Short-circuit protection
In addition to the functions listed in Table 1,the calibrator also has the following characteristics:
1,A split-screen display. The upper display allows users to measure volts, current, and pressure only.The lower display allows the user to measure and source volts, current, pressure, resistance temperature detectors, thermocouples, frequency,and ohms.
2,A thermocouple (TC) input/output terminal with cold junction temperature compensation,ambient temperature can be set and calibrate within the menu function.
3,Each parameters can manual and automatic stepping and ramping output, signal output can be arbitrarily set within the 0% and 100% of the value. (In addition to the pressure output)
4,In the configuration menu can be set manually : Power off time for Instrument, Backlight off time, Screen Contrast, Cold junction compensation ON/OFF,HART resistence ON/OFF and ETC. You can also set the output amplitude and duty cycle for frequency manually in configuratiion menu.
5,Have calendar clock function,it can be calibrated in configuration menu.
6,It can be store 8 sets of measurement and output data and call the showing at any time,all the settings and the functions of the last operation be auto-stored after power off.
7,The Calibrator and pressure module is hot-plugging, not need to turn off power, adaptive communications, abundant optional fitting.(Pressure module,Pressure pump,Adapter)
8,High capacity rechargeable battery pack, with power adapter,within integrated charge-management functions.
9,Novel shape,large screen dot-matrix graphic display, can display chinese characters,digital key to input personalized , make the operation more simple.