Accuracy | Current, voltage 0.2 class, Frequency 0.1Hz, Power, Active electric energy 0.5class, Reactive electric energy 2 class | Display | LCD Display | Input measurement | Network | Three Phase Four Line, Three Phase Three Line | Rated value | Voltage AC100V, AC400V, Current AC1A, AC5A | Overloading | Continuance: 1.2 times, Instantaneous: Voltage 2 time(10s) Current 10 times(5s) | Power consumption | Voltage< 0.6VA(each phase), Current< 0.4VA(each phase) | Impedance | Voltage circuit> 300kΩ |
|
input measurement | Frequency | 50Hz± 10% | Harmonics | Voltage, Current(2~31 time) harmonic | Mnlti-rate electric energy | 3 rates, 8 time bands | Clock/Calendar | Clock error 0.5s/day | Oiwer syooky | Working range | AC, DC 80V~270V | Power consumption | ≤ 5VA | Output | Digital Interface | RS-485 interface, MODBUS-RTU protocol | Pulse output | 2 loops power pulse output, Photo-coupler relay, Constant: 3200imp/kWh(kvarh) | Switch value output | 2 loops light coupler | lnstallation | Installation mode | Panel mounting | Cutout size | 92x92mm | Outline dimension | 96x96x100mm | Operation condition | Ambient temp: -10~55° C, Relative humidity≤ 93%, No corrosion air, Height (above sea level)≤ 2500m | Isolation withstand voltage | Input and power supply> 2kV, Input and output> 2kV | Insulating resistance | ≥ 100MΩ |
| Table for Detail Function | |
| Three Phase Four Line | Three Phase Three Line | Phase voltage | Ua, Ub, Uc | — | Line voltage | Uab, Ubc, Uca | Uab, Ucb | Current | Ia, Ib, Ic | Ia, Ic | Active power | Pa, Pb, Pc, P | P | Reactive power | Qa, Qb, Qc, Q | Q | | Three Phase Four Line | Three Phase Three Line | Apparent power | Sa, Sb, Sc, S | S | Power factor | PFa, PFb, PFC, PF | PF | Voltage harmonics | Ua, Ub, Uc (2~31times) | Uab, Ucb (2~31times) | Current harmonics | Ia, Ib, Ic (2~31times ) | Ia, Ic (2~31times) | Voltage unbalance degree | Yv | Current unbalance degree | Yi | Voltage component | Positive sequence Up, Negative sequence Un | Current component | Positive sequence Ip, Negative sequence In | Frequency | F | Active energy | +kWh, -kWh | Reactive energy | +kvarh, -kvarh | Time-sharing calculating | Peak, Shoulder, Vally, Total | SOE event reording | 20 pieces SOE event recording | Remote surveillance input | 2 loops of switch value input | Remote control output | 2 loops of switch value output | Communication interface | 1 loop of RS-485 interface, MODBUS-RTU | Pulse output | 2 loops of energy pulse output | Referenced application | Electric power system, Transformer, Gen-sets low voltage system wire-in, Energy measurement, Communication and management |
|