Multi-function Watt-hour Meter;
High integration;
Good stability;
Three-phase;
Multi-function Watt-hour Meter DT(S)SD988;
Port: Guangdong
Minimum Order Quantity: Negotiable
Supply Ability: 1000000 Unit/Units per Year
Payment Terms: L/C,D/A,D/P,T/T,Western Union
Contact SupplierPackaging Detail: In cartons with different demensions for different type of meters
Delivery Detail: Subject to technical requirements and amount of order
Three-phase Electronic Multi-function (Checking within transformer district) Watt-hour Meter DT (S) SD988
Introduction of products
DT (S) SD988-type three-phase electronic multi-function (checking within transformer district) watt-hour meter is a newly multi-function meter, with special application in low-voltage power spots to accomplish checking and management of power within the transformer district. The products have adopted advanced measurement chip and communication chip, featured with high integration, high precision, good stability, reasonable layout, advanced technology, great utilization, powerful function, friendly operation, etc.
Functions
Power Measurement function
Make time-measuring of positive and negative power (active and reactive), and four-quadrant reactive power.
Maximum power demand metering
Make time-measuring of the maximum positive and negative power (active and reactive) demand. And it has power demand resetting function.
Multi-rate function
It can program 4 rates, 10 day time consumption, 5 day time consumption table, 4 time zones and 12 public holidays.
Freeze function
Freeze and store automatically the power consumption at each hour of the custom day, at the end of time zone, on the custom day of automatic meter reading.
Load curve function
According to users’ settled time, it will execute curve record about the 6 selected groups of data in interval, and the shortest recording interval is up to one minute.
Events recording function
Record various events such as loss of voltage, loss of current, voltage passing rate, power-off or power-on state, programming, power demands clearing, broadcasting timing, etc.
Three-phase (without voltage) current detection
It can record the latest occurring time of current (without voltage), as well as its total degree and accumulated time.
Alarm function
Support the light-control alarm and voice-control alarm.
Swift tripping in the case of overload
The meter will output swift tripping signal when the load exceeds the settled load value.
Main technical parameters
Accuracy Class | Active : 1, 0.5, 0.5S Reactive: 2 |
Reference Voltage Un(V) | Three-phase and four-wire:(DTSD988): 3×57.7/100 3×220/380 Three-phase and three-wire:(DSSD988): 3×100 |
Operating Voltage | 0.7 Un~ 1.2 Un |
Rated Current Ib(A) | 3×0.5(2),3×1(2),3×1.5(6),3×3(6),3×5(20) |
Starting Current | Active : 0.005Ib(G2),0.004Ib(G1) Reactive: 0.003Ib(G2) |
Rated Frequency | 50Hz |
Power Consumption | Voltage circuit: ≤ 2W, 5VA Current circuit: ≤ 2.5VA |
Display Mode | LCD |
Communication Interface | Infrared, the second channel RS485, low-voltage power line carrier |
Overall Dimensions | 296mm´173mm´77mm |
Weight | About 2.4kg |
Work Environment | Normal operating temperature: -30°C~+55°C Limit of operating temperature: -45°C~+70°C Storage and transport temperature: -45°C~+70°C Storage and Operating humidity: ≤95% |