Milwaukee Mi180 measures 6 different parameters: pH, ORP, EC, TDS, percentage of NaCl and temperature in a variety of ranges.

Mi180 measures 6 different parameters: pH, ORP, EC, TDS, percentage of NaCl and temperature in a variety of ranges.

The Milwaukee Mi180 measures 6 different parameters: pH, ORP, EC, TDS (Total Dissolved Solids, percentage of NaCl and temperature in a variety of ranges. pH calibration can be performed in 3 points selectable between 7 memorized buffers, to provide a very accurate calibration curve even when testing different samples, where very wide differences in pH can be found.

The Milwaukee Mi180 auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user.

The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy. Conductivity readings are performed with the 4-ring probe supplied with the meter. The GLP feature allows users to store and recall data on system status. PC compatible through an RS232 port or USB.

Technical Specification

RangepH-2.00 to 16.00 pH; -2.000 to 16.000 pH
ORP± 699.9 mV; ± 2000 mV
EC0.00 to 29.99 µS/cm; 30.0 299.9 µS/cm;
300 to 2999 µS/cm; 3.00 to 29.99 mS/cm;
30.0 to 200.0 mS/cm; up to 500.0 mS/cm actual conductivity (uncompensated EC*)
TDS15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS (with .080 factor)
NaCL0.0 to 400.0%
Temp-20.0 to 120.0°C
ResolutionpH0.01 pH; 0.001pH
ORP0.1 mV; 1 mV
EC0.01 µS/cm; 0.1 µS/cm; 1.0 µS/cm;
0.01 mS/cm; 0.1 mS/cm
TDS0.01 mg/L; 0.1 mg/L; 1.0 mg/L; 0.01 g/l; 0.1 g/l
NaCL0.1%
Temp0.1°C / 0.1°F
AccuracypH± 0.01 pH; ± 0.002 pH
ORP± 0.2 mV; ± 1 mV
EC± 1% of reading ± (0.05 µS/cm or 1 digit)
TDS± 1% of reading ± (0.03 ppm or 1 digit)
NaCL± 1% of reading
Temp± 0.4% / ± 08°F
Rel mV Offset± 2000 mV
CalibrationEC - 1 point slope calibration with 6 memorized solutions available (84.0 µS, 1413 µS, 5.00 mS/cm, 12.88 mS/cm 80.0 mS/cm, 111.8 mS/cm)
NaCL -1 point, with MA9066 calibration solution
Temp CompensationAutomatic or Manual, from -20.0 to 120.0°C
Temp CoefficientSelectable from 0.00 to 6.00% / °C (EC and TDS)
pH ElectrodeMA917B/1 - included
EC ProbeMA831R - included
TDS Factor0.40 to 0.80 (default value is 0.50)
Log on demand50 on each range (pH, mV, EC, TDS, NaCL)
GLPLast pH, EC, NaCL calibration data
PC InterfaceRS232 / USB Opto-isolated
Environment0 to 50°C / 32 to 122°F; max RH 95%