Home  >  Level Measuring Instruments

Microcomputer Induced Polarization Receiver - GWM00372

We have a lot of agricultural and industrial machinery,Welcome consulting. - more info check here: http://www.buymeasuringtools.com/Microcomputer-Induced-Polarization-Receiver-10158012/

Quick Brief

Model Number: GWM00372

Product Features:

We have a lot of agricultural and industrial machinery,Welcome consulting.

Business Terms:

Contact Supplier
Microcomputer Induced Polarization Receiver
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

Applications

This is a micro-computerized time domain induced polarization receiver designed for high productivity surveys in engineering geology, metallic and nonmetallic mineral exploration, and groundwater investigation.

This instrument has the ability to measure multiple parameters directly, including self-potential, primary potential and polarizability. It can be widely used for metallic and non-metallic deposits investigation, groundwater resources detection and engineering geological exploration.

this Microcomputer Induced Polarization Receiver can be used not only for induced polarization survey but also for resistivity survey. In addition to standard surface measurement, this also can be applied for continuous induced polarization logging and borehole induced polarization measurement.

Key Features

• Strong anti-interference capability and high precision with digital filtering and signal amplification.
• Compensating self-potential, drift and electrode polarization automatically.
• Transient over-voltage protection.
• Large color display, Chinese character keyboard, Chinese menu.
• Measured parameters and observational curves can be displayed on the screen directly and concisely.
• Ability to measure and store multiple parameters such as self-potential, primary potential, output current (under synchronous mode ), apparent resistivity, apparent polarizability, half decay time, degree of decay, degree of deviation, induction number and so on.
• Power-cut protection: 1MB data can be stored and not to be lost when closedown or changing battery.
• All sealed constitution: water-proof and dust-proof design, long operational life span.

Technical Specifications

• Primary Potential Measurement: Resolution ±1μV ; Range 20V (Max)
• Current Measurement: Resolution 1mA; Range 20A (Max)
• Downhole Measurement: Depth count resolution 0.01m; Range 99.99m (Max)
• Polarizability Measurement: Resolution 0.001%
• Measuring Accuracy: ±1%±1digit for voltage,
current and apparent polarizability
• Input Impedance: ≥100MΩ
• Noise Reduction: better than 80dB for 50Hz power frequency
• Operating Temperature: -10°C~50°C
• Operating Humidity: 95% RH (Max)

Microcomputer Induced Polarization Receiver suppliers    Microcomputer Induced Polarization Receiver manufacturers