MYHT-1-5 Lightweight Hydraulic Testing Tools
1accurate measurement
2gross weight:32kg
3.pressure:420bar
4.net weight:10.2kg
Port: Qingdao
Minimum Order Quantity: 1 Unit/Units
Supply Ability: 100 Unit/Units per Year
Payment Terms: T/T
Contact SupplierPackaging Detail: in Box or according to customers' requirements
Delivery Detail: about 15 days
Lightweight Hydraulic Testing Tools
The Myth Digital Portable Hydraulic Tester is an all-in-one unit designed to test the performance of hydraulic pumps , motors ,valves and hydrostatic transmissions .
The easy-to-use design allows the operator to just switch on and test , without cornptex setup or special training .
The Myth is the ideal tool for pinpointing hydraulic system faults ,reducing downtime,and helping preventative maintenance .
Simple operation includes a toggle switch to display either flow or temperature readings and a built-in loading valve is specifically designed to enable the operator to simulate the maximum working pressure safely during normal machine operation .
Features
1. Accurate measurement of flow ,pressure, peak pressure and temperature .
2. Safe to use in both directions of flow. Internal oil by-pass protects muitimeter and operate against overpressure
3. Bi-directional for unrestricted connection and simplified testing.
4. Fast checks on pumps ,motors, valves ,cylinders ,hydrostatic transmissions.
5. Easy to operate controls. Connect into the hydraulic system and simply ‘switch on”.
6. Portable and lightweight with the case for easier viewing and cleaning.
7. Rechargeable power: lithium battedes 12v.
Installation
MYTH series hydraulic tester can be installed at any point in hydraulic pipeline .The hydraulic oil flow from input to output (input) of the hydraulic tester must keep over 30cm from elbows /the links and valves.
Attention: You must open the loading valve when you start the instrument .If the loading valve is closed , it is dangerous.
1) Once the hydraulic tester works ,it could be regulated by loading valve.
2) The cold weather could effect the testing precision ,when the hydraulic oil keeps about 30? The hydraulic tester could work well.
3) Please close the switch after testing.
4) Please open pressure loading valve before testing.
Technical Specifications
model | Max flow (LPM) | Max pressure(bar) | Temperature | Precision | Dimension(mm) | Weight(KGS) |
MYHT-1-2 | 200 | 420 | 150°C | ±1% | 295x265x210 | 6.1 |
MYHT-1-4 | 400 | 420 | 150°C | ±1% | 295x265x210 | 8.8 |
MYHT-1-5 | 500 | 420 | 150°C | ±1% | 295x265x210 | 10.2 |
MYHT-1-7 | 800 | 420 | 150°C | ±1% | 310x285x261 | 14 |