pH + Conductivity Double-Parameter measurement meter which is suitalbe for general measurement in laboratory.
Port: Shanghai or Tian Jin or Xi'an
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 100 Set/Sets per Month
Payment Terms: L/C,T/T,Western Union
Contact SupplierPackaging Detail: Paper Box
Delivery Detail: 15days
pH | Measuring range Resolution Accuracy Input current Input impendance Stability Temp. compensation range | (-1.99 ~ 19.99)pH 0.1/0.01/0.001 pH Meter:±0.01pH, connect meter with electrode:±0.01pH ≤1×10-12 A ≥3×1012 Ω ±0.01 pH/3h (0 to 100) °C(automatic or manual) |
mV | Measuring range(mV/ORP/EH) Resolution Accuracy | -1999.9mV ~ 0 ~ 1999.9mV 0.1mV ±0.03% FS |
Conductivity | Measuring range Resolution Accuracy Temp. compensation range Electrode constant Reference temperature | Conductivity:(0.00~20.00)μS/cm (20.0~200.0)μS/cm (200~2000)μS/cm (2.00~20.00)mS/cm (20.0~200.0)mS/cm Resistivity:(0 ~ 100)MΩ·cm TDS: (0 ~ 100)g/L Salinity: (0 ~ 100)ppt 0.01/0.1/1μS/cm 0.01/0.1/1 mS/cm Meter:±1.0% FS,connect meter with electrode:±1.5% FS (0 ~ 50)°C(automatic ) 0.1 / 0.5 / 1 / 5 / 10 / 50 / 100 cm-1 25°C,20°C and 18°C |
Temperature | Measuring range Resolution Accuracy | -10°C~ 110°C 0.1°C 5~ 60°Crange:±0.4°C other range:±0.8°C |
Other Technical Parameters: | Data storage Storage content Power Communication connector Size and weight Quality and safety certification | 300 groups Measuring value series number, measuring value, temperature, ATC or MTC state, measuring date and time DC9V/300mA RS232 160 × 190 × 70mm/880g ISO9001:2008, CE and CMC |
Working Condition | Environment temperature Environmental humidity IP rating | 5 ~ 35 °C(0.01grade) 15 ~ 30 °C(0.001grade) ≤75% IP54 Dustproof and waterproof |
1. The most widely used pH + Conductivity Double-Parameter measurement meter. |
2.Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc. |
3. There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode. |
4. Automatically recognize pH buffer solution. User can choose anyone from three series of standard buffer solutions: Europe & USA series, NIST series and China series. |
5.Adopt advanced and original conductivity measurement technology, use 1 pc of conductivity electrode (K=1), it can meet measuring accuracy requirement for range within 0.5μS/cm ~ 200mS/cm by using only one-point calibration. |
6.Can switch Conductivity, TDS, Salinity and Resistivity. |
7. Meter has the only product serial number. |
8. Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps. |