MITECH LX-F Shore Hardness Tester - LX-F

1. Easy to use and carry, 2. Efficiant and accurate measurement, 3. Pointer display, esay to read - more info check here: http://www.buymeasuringtools.com/MITECH-LX-F-Shore-Hardness-Tester-10160851/

Quick Brief

Place of Origin: Beijing China (Mainland) Brand Name: Mitech Model Number: LX-F Scope of pressure needle route: 0~2.5 mm Scale value: 0-100 degree Pressure: 550mN~4300mN(56~438.5g)

Product Features:

1. Easy to use and carry

2. Efficiant and accurate measurement

3. Pointer display, esay to read

Business Terms:

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 50 Set/Sets per Week

Payment Terms: T/T,Western Union,Paypal

Contact Supplier
MITECH LX-F Shore Hardness Tester
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Export Standard Carton

Delivery Detail: Within 2 workdays against receiving the fund

Specifications and Product Details:

1. Introduction:

First,in order to measure the hardness of foam, we special tailor-Made the LX-F type

sponge durometer to facilitate our customers. It is suitable for the determination of

soft foam,polyurethane foam rubber products’hardness.And itwill be different with

the other hardness tester In the aspects of using.When using,the presser foot directly

contact to the sample,and see it sown weight as force measuremen tload.

2.Main parameters:

1. Scope of pressure needle route:0~2.5millimeters.

2. The scale value:0-100 degrees.

3. The force of pressure needle end:550mN~4300mN(56~438.5g).

3. How to use:

Held the middle of the instrument,located the hardness tester gently on the plane

Specimens which is bigger than presser foot(orspecimen).Reading out the value in

1 second when durometers’presser foot contact with the samples moothly.And the tick

of pointers is the hardness value of sample (specimen). In order to improve the

accuracy of measurement, you should putthe sample on a flat plate glass or plate.

Each measuring point should be measured only on

4. Attention:

1 When the durometer presser foot is in the free state, it points "0".The pressure

needle end and the pressure foot flat is in close contact with the glass surface, the

indication should be "100" If the Durometers’ pointer can notshow “0’ and “100”

whenchecking,adjustitto“0’and“100

2, The sample and adjustments

The specimen thicknesss houldbe in 25mm to 30mm,when insufficient thickness

Of 25mm,you can stack 2 pieces.but you need to ensure the flat surface smooth,

The whole thicknesss tills hould conform to the sample thickness.

The sample size should satisfy thel ength and the width are larger than100mm,

The distance between the measuring point and sample edge is not less than 40mm,

All measuring point are less than between 25mm,each sample pointsi s not less

Than five points.

Take out the skin of both sides of the specimen,the thickness should be uniform,

smooth surface, micro-hole distribution uniformity,no mechanical damage and

impurities.

SampletestconditionsaccordingtoGB/T2941-91provisions.

3,Afterusingthehardnesstester,putitininstrumentbox,putindryplacetoprevent

moisture.

Subsequent: welcome users to make more precious suggestions in aspects of

performance,structure,manufacturingqualityetc.forourimprovementandimprove

productquality.