MGC3000 Portable gas chromatograph
No need manual sampling,
the latest international rescuing gas analysis and test equipment
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 100 Set/Sets per Month
Contact SupplierPackaging Detail: standard package
Delivery Detail: 20-30day from the prepament
Name: MGC3000 Portable gas chromatograph
Brand: Topsky
Type: MGC3000
Quick introduction: on the ground,the machine automaic adopts the gas in Disaster scene and Real-time analysis on-line, not need sampling manual. It can test and analysis of the common gas in mining, including: H2,O2,N2,CO,CO2,CH4 Ethane, ethylene, acetylene, propane, butane, pentane and C6-C8, supplies the Basis for decision making for Rescue command, Automatic sampling distance more than 2km.
No need manual sampling, the latest international rescuing gas analysis and test equipment
MGC3000 Portable gas chromatograph
Realized automatic distanced sampling from disaster scene, avoiding secondary accident once manual sampling.
First, functions and applications
can test and analysis of the common gas in mining, including: H2,O2,N2,CO,CO2,CH4 Ethane, ethylene, acetylene, propane, butane, pentane and C6-C8, supplies the Basis for decision making for Rescue command
on the ground,the machine automaic adopts the gas in Disaster scene of underground mining and Real-time analysis on-line, not need sampling manual(optional)
Automatic sampling distance more than 2km(optional)
Mobile trolley system, easy and fast to move the main engine(optional)
Second. Technical specifications
1,Minimum detectable concentration(unitµL/L)
Gas type | concentration range | The minimum limit detective | priority |
O2 | 1%-21% | 0.10% | 1 |
N2 | 1%-100% | 0.10% | 2 |
co | 0.5ppm-10000ppm | 0.5ppm(ralax to 5ppm) | 1 |
CO2 | 0.01%-20% | 10ppm(cap may not be considered) | 1 |
methane | 0.01%-20% | 1ppm | 1 |
ethane | 0.01%-20% | 1ppm | 2 |
ethylene | 0.01%-1% | 0.5ppm | 1 |
acetylene | 0.01%-1% | 1ppm | 2 |
propane | 0.01%-5% | 1ppm | 3 |
tetrane | 0.01%-5% | 1ppm | 3 |
2,Qualitative reproducibility:error≤1%
3,Quantitative reproducibility:error≤3%
l Detector technology index
Thermal conductivity detector(TCD) | Hydrogen flame ionization detector(FID) |
Semi diffusion type structure | Cylinder type collecting electrode structure design,Quartz Nozzzle,response good |
Power adopted Constant current control mode | automatic ignition;settling time:10mins |
sensitivity:≥2500mV·ml/mg(n-hexadecane /isooctane) | detectability:≤8×10-12g/s(n-hexadecane /isooctane) |
baseline noise:≤20μV | baseline noise:≤2×10-13A |
baseline shift:≤100μV/30min | baseline shift:≤2×10-12A/30min |
Linear:≥104 | Linear:≥106 |
room temperature 8°C~399°C accuracy±0.1°C
size:450*430*230mm
weight:<15kg