lensmeter internal reading 25D with compensation
Port: Shanghai
Minimum Order Quantity: 1 Piece/Pieces
Payment Terms: L/C,T/T,Western Union
Contact Supplier
Features | 1.Model FLS-03 Lensmeter is used to measure the dioptres is spherical lens and cylinder lens,the axis of cylinder lens,the strength and the baseline direction of shuttle lens,It can also stamp the optical center of lens,the axis of cylinder lens and the base direction of shuttle lens. | 2.This instrument(Both AC and DC are permitted.Two 5# cells when DC) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently.In addition,it has the compensation lens to correct the optical point center.AU the lenses and the made glasses can be measured by it,which,therefore,is a required and ideal measuring instrument for glasses manufacturers,glasses stores and ophthalmological hospitals. | Technical parameter: | 1.Eyepiece focusing range:±5D | 2.The top point dioptre measuring range:-25D-+25D | 3.The minimum measuring square value:0.125D | 4.The shuttle lens measuring range:10 | 5.The shuttle lens square value:1 | 6.The cylinder lens axial range:0-180° | 7.The cylinder lens axial square value:1° | 8.The maximum diameter of the measured lenses:100mm | 9.The lighting:AC 220v/110v-6v DC 3v |
The Uses And The Features | |||
Model FLS-03A Lensmeter is used to measure the dioptres is spherical lens and cylinder lens,the axis of cylinder lens,the strength and the baseline direction of shuttle lens,It can also stamp the optical center of lens,the axis of cylinder lens and the base direction of shuttle lens. | |||
Bitmap This instrument(Both AC and DC are permitted.Two 5# cells when DC) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently.In addition,it has the compensation lens to correct the optical point center.AU the lenses and the made glasses can be measured by it,which,therefore,is a required and ideal measuring instrument for glasses manufacturers,glasses stores and ophthalmological hospitals. | |||
MAIN PARAMETER | |||
1.Eyepiece focusing range:±5D | |||
2.The top point dioptre measuring range:-25D-+25D | |||
3.The minimum measuring square value:0.125D | |||
4.The shuttle lens measuring range:10 | |||
5.The shuttle lens square value:1 | |||
6.The cylinder lens axial range:0-180° | |||
7.The cylinder lens axial square value:1° | |||
8.The maximum diameter of the measured lenses:100mm | the other side | ||
9.The lighting:AC 220v/110v-6v DC 3v |