Measuring the volume of cold ptable water passing through the pipeline.
Payment Terms: L/C,T/T,Western Union,MoneyGram
Contact Supplier
Measuring the volume of cold ptable water passing through the pipeline.
Liquid sealed register,small starting flow rate for wet type,long term clear reading for dry type type rtc.
Particulary suited in lower quality water.
Working Condition:
Water temperature:≤40
Water pressure:≤1Mpa
Maximum Perissible Error
a)In the lower zone from Qmin inclusive up to but excluding Qt is ±5%
b)In the upper zone from Qt inclusive up to and including Qs is ±2%
Type | Size mm | Class | qs Max Flow | qp Nominal flow | qt Transitional flow | qmin Min. Flow | Min. Reading | Max Rreading | Length L | Width B | Height H | Connecting Thread D | Weight Kg |
m3/h | L/h | m3 | mm | ||||||||||
LXS-15F | 15 | A | 3 | 1.5 | 0.15 | 60 | 0.00005 | 99999 | 145/165 | 94 | 115.5/110.5 | G 3/4B | 1.5/1.6 |
B | 0.12 | 30 | |||||||||||
C | 0.0225 | 15 | |||||||||||
LXS-20F | 20 | A | 5 | 2.5 | 0.25 | 100 | 0.00005 | 99999 | 190/195 | 94 | 117/112 | G 1B | 1.7/1.8 |
B | 0.20 | 50 | |||||||||||
C | 0.0375 | 25 | |||||||||||
LXS-25F | 25 | A | 7 | 3.5 | 0.35 | 140 | 0.00005 | 99999 | 260/225 | 118 | 126/122 | G1 1/4B | 2.5/2.2 |