1.Measuring Range: 0-150mm/0-6in
2.Material:stainless steel (4cr13)
3.Four-way measurements
4.certificate:CE
5.Display: LCD
Port: Ningbo or Shanghai
Minimum Order Quantity: 1000 Set/Sets
Supply Ability: 100000 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: outer box size:48*27*32 cmQTY:50 pcsG.W/N.W:19/17 kg
Delivery Detail: 30 days after deposit receiving.
LCD screen digital vernier Calipers for measuring (E005)
SPECIFICATIONS
1. size: 23.6cm
2. material: stainless steel(4cr13)
3. packing details:
QTY PER CTN | N.W/G.W | CTN SIZE |
50PCS | 17/19KG | 48*27*32 cm |
TECHNICAL SPECIFICATIONS
Outside Jaws: Measure External Length
Inside Jaws: Measure Internal Length
Measuring Range: 0-150mm/0-6in, 0~200mm/ 0~8 in
Resolution: 0.01mm/ 0.0005in
Accuracy: ± 0.02mm/ 0.001in (<100mm)
±0.03mm/0.001in(>100-200mm)
Repeatability: 0.01mm / 0.0005in
Max Measuring Speed: 1.5m/sec, 60in/sec
Measuring System: Linear Capacitance measuring system
Display: LCD Screen
Material: Stainless Steel(4CR13)
Power: One alkaline lithium button cell battery 1.5v,TYPE LR44.
Capacity-180MAH
Working Temperature: 5°c-40°c/41 to 104 degree f
Note: Accuracy affected in environments exceeding 80% relative humidity.
APPLICATIONS
1.Operation : slider can be removed only after the locking screw (#10) is loosened.
2.Basic measuring methods :
1) loosen the locking screw
Press "ON " button, select sae or metric measurement by pressing "MM/INCH" button.
Pressing "MM/INCH" button after measurement will display the sae / metric conversion.
3)To reset display to zero, close external measuring jaws, then press "ZERO" button
MAINTENANCE INSTRUCTIONS
1. Keep the calliper clean and dry (liquid can damage the slider)
2. Use a clean, dry cloth to clean all surfaces -do not use solvents or solvent based cleaners.
3. To save power, turn off the unit when not in use.
Avoid contact with electricty and /or electronic devices.
BATTERY REPLACEMENT
Flashing display indicates low battery. To replace battery, remove battery cover by sliding
cover in the direction indicated and replace battery with positive side facing out.
TROUBLE SHOOTING
failure | cause | measure |
display flashes | low battery | replace battery |
display does not change when slider is moved | system locked | remove battery and replace after 30 seconds to reset system |
accuracy less than +/-0.001mm | dirt in the sensor | remove slider cover and its assembly,clean withcompressed air 5kg/cm2 |
no display on LCD | 1.improper battery position 2.low battery | 1.remove battery cover and check battery position 2.replace battery |