1. FIELDVUE DLC3000 Level Controller
2. Stable Performance
3. Endurable
4. 420C Class 2500
Port: Shanghai
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 1000 Set/Sets per Week
Payment Terms: L/C,T/T,Western Union
Contact SupplierPackaging Detail: at requested
Delivery Detail: within 25 days after deposit
Technique Parameter
Measure range: 0~3000m
Accuracy: ±0.5%FS; ±0.1%FS
Linearity: ±0.5%FS
Hysteresis: <0.2%FS
Repeatability: ±0.1%FS
Dead area: <0.2%FS
Power supply: 12V~30VDC; with reverse power protection in controller;
Output: Analog 4~20mA (direct); 20~4mA
Digital: HART1200 FSK
LCD: display analog value or level, temperature, torque tube rotation angle and % range.
Min density difference: 0.05g/cm3
Enclosure: NEMA4X and IEC60529 IP66
Model Table
LC3010 | Intelligent Displacer Liquid Level (Interface )Transmitter | Model Number | |||||||||
1 | HART | Communication | |||||||||
2 | F. FIELDBUS | ||||||||||
3 | FOMCOM | ||||||||||
1 | Q235 STEEL | Body Material | |||||||||
2 | 321 SCS321 1Cr18Ni9Ti 1.4873 | ||||||||||
3 | 316Ti OCr18Ni12Mo2Ti 1.4571 | ||||||||||
4 | 316 SVS316 OOCr17Ni12Mo2 1.4401 | ||||||||||
5 | 316L SVS316L OOCr14Ni12Mo2 1.4435 | ||||||||||
6 | other material to be specified. | ||||||||||
H | External displacer side-side mounted | Mounting | |||||||||
C | External displacer side-bottom mounted | ||||||||||
F | External displacer top-side mounted | ||||||||||
G | External displacer top-bottom mounted | ||||||||||
N | Internal displacer top mounted | ||||||||||
1 | For liquid level | Service | |||||||||
2 | For interface | ||||||||||
3 | For density | ||||||||||
4/4A | 2.5MPa/Class 150LB ANSI | Pressure | |||||||||
5/5A | 4.0MPa/Class 300LB ANSI | ||||||||||
6/6A | 6.3MPa/Class 600LB ANSI | ||||||||||
7/7A | 16.0MPa/Class 900LB ANSI | ||||||||||
8/8A | 32.0MPa/Class 1500LB ANSI | ||||||||||
9/9A | 40.0MPa/Class 2500LB ANSI | ||||||||||
T1 | Normal temp.:-40°C~150°C | Process | |||||||||
T2 | High temp.-150°C~400°C | ||||||||||
T3 | Low temp.-196°C~150°C | ||||||||||
O | No explosion-proof . | Safety Class | |||||||||
D | Explosion-proof: ExdIICT1~T6 | ||||||||||
E | Intrinsically safe: ExiaIICT1~T6 | ||||||||||
B | with safety barrier (See Operation Manual) | ||||||||||
0 | without heating jacket | Accessories | |||||||||
J1 | heating jacket / process conn. | ||||||||||
J2 | heating jacket / process conn. | ||||||||||
Measure Range | |||||||||||
Medium Density |