Home  >  Temperature Instruments

JC-502 temperature controller - JC-502

1.Temperature controller, 2.Temperature display (Celsius/Fahrenheit degrees), 3.Manual, automatic defrost by turning off - more info check here: http://www.buymeasuringtools.com/JC-502-temperature-controller-10137349/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: juchuang Model Number: JC-502 Usage: temperature controller Theory: Temperature Controller

Product Features:

1.Temperature controller

2.Temperature display (Celsius/Fahrenheit degrees)

3.Manual, automatic defrost by turning off

Business Terms:

Minimum Order Quantity: 500 Unit/Units

Supply Ability: 99999 Unit/Units per Month

Payment Terms: T/T

Contact Supplier
JC-502 temperature controller
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

temperature controller

·Temperature display (Celsius/Fahrenheit degrees)

·Temperature control

·Manual, automatic defrost by turning off

·Time or temperature setting to end defrost

·The cold-room sensor temperature can lock during defrost

·Parameter sets and value storing

·Compressor re-start delay

·Parameter locking

·The factory default resumption

·Offset on sensor temperature ·Self testing

·Power supply220V/AC~240V/AC50/60Hz 110V/AC~120V/AC60Hz
·Power consumpotio n5W
·Output relay for compressorN.O.30A/250V~50/60Hz.
·Temperature sensorNTC,2 sensor(Temp. Display , defrost control)
·Temperature unit/Change ·Resolution1
·Accuracy±1±2
·Range of temperature control-45 ~ 45-40 ~ 120

ParameterFunctionSet rangeDefault
PAMenu password00 ~ 9900

E1

Lower set point limit

-45 ~ Set temperature-15
-40 ~ Set temperature05

E2

Higher set point limit

Set temperature ~ 4510
Set temperature ~ 12050

E3

Temperature hysteresis

01 ~ 1005
01 ~ 3607
E4Comp. Start delay time00 ~ 10Min00
E5Offset on room temp.-05 ~ 05/00
E6Offset on evep. temp.-05 ~ 05/00
F1Max. Defrost duration01 ~ 60 Min20
F2Defrost interval time00 ~ 24Hr06

F3

Defrost termination temp.

00 ~ 4512
32 ~ 11054

F4

Display during defrost

00=Normal display

01

01=Last value before defrost

C1

Temperature unit

00=

00

01=
CPAChanging menu password00 99Setting00, the menu password is cancelled00