DIN rail Temperature Transmitter of Thermal Resistor
input voltage range: 18V~30V DC
output signal range: 4~20mA 0~20mA 1~5V
Port: Tianjin
Minimum Order Quantity: 5 Piece/Pieces
Supply Ability: 3000 Piece/Pieces per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: standard package
Delivery Detail: 4 weeks
Description of product
R5S series intelligent digital temperature transmitter with thermal resistor, used for industrial automation system, receive thermal resistance signal input from industrial field, convert it to analog output corresponding temperature in proportion, isolate and transmit to DCS/PLC, which realizes the temperature gathering and transmitting in industrial field, meanwhile meet with signal types matching, isolation, interference rejection and improve the system stability function between DCS/PLC. Input and output signals of products in this series can change range through software, adjust through digitization, automatically dynamic calibration offset, automatically cover temperature drift and other functions. This product contains one in-one out, one-in two-out, two in-two out a variety of combination forms. Width of the shell is only 12mm, which satisfies the high-density requirements of on-site installation.
General specifications | |
Construction | Ultra-thin terminal connections |
Connect | Phoenix terminals M3 screw connection |
Wire diameter | 0.2-2.5mm2 |
Tightening | 0.5-0.6Nm |
Housing material | Fire resin |
Protection grade | IP20 |
Mounting | EN60715 standard symmetric rail 35mmDIN |
Dimensions | W12 x H95 x D110 mm |
Weight | Approx. 100g |
Input specifications | |||||||||
Input voltage range | 18V~30V DC | The Power of full-load | ≤2W | ||||||
Absolute maximum input voltage | 30VDC | The Power of no-load | / | ||||||
Power reverse-phase protection | Yes | Power overload protection | Yes | ||||||
Input signal specifications | |||||||||
Input signal range | Three-wire system input,PT100,Cu50,Cu100 configurable PT100 Temperature measuring range: -200°C ~ 850°C Cu10 Temperature measuring range: -50°C ~ 150°C | ||||||||
Range of wire resistance | ≤200W | ||||||||
Current source | ≤ 1mA | ||||||||
Minimum measure range | 50°C | ||||||||
Output signal specifications | |||||||||
Output signal range | 4 ~ 20mA, 0 ~ 20mA, 1 ~ 5V, 0 ~ 5V, 0 ~ 10V signal types such as output | ||||||||
Output signal resistance | 0/4~20mA Output: 0~550W (Take short circuit protection) | ||||||||
0~10mA Output: 0~1100W (Take short circuit protection) | |||||||||
0/1~5V Output: ≥500KW (Take short circuit protection) | |||||||||
0~10V Output: ≥1MW (Take short circuit protection) | |||||||||
Fault output | output | 4~20mA | 0~20mA | 1~5V | 0~5V | 0~10V | |||
Input disconnection | About is 23mA | About is 23mA | About is 5.75V | About is 5.75V | About is 11.5V | ||||
Input super range limit | 3mA | 21mA | 0.75V | 5.25V | 10.5V | ||||
Input super span ceiling | 22mA | 22mA | 5.5V | 5.5V | 11V |
Typical application field:
Ø Transfer thermal resistance or potentiometer signal into isolated standard signal.
Ø Field existing grounding potential difference.
Ø Field existing heavy electromagnetic interference.
Ø Protecting DCS or PLC system.
Ø Distributing one signal in two ways.
If you have any questions, please feel free to contact with us