1.CE Certificate
2.Signal quality tracking and self-adjusting
3.Data logger function
4.High accuracy
5.Hot-tapped type
Port: Shanghai
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 500 Set/Sets per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: Carton as per export standard.
Delivery Detail: Within 7 workdays
The wall-mounted Insertion Transit Time Ultrasonic Flow meter provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
Features:
1,Hot-tapped Installation, no pipe line flow interrupted.
2, internally configured batch controller makes batch control convenient and accurate.
3, Spool-piece transducer for best accuracy with long-term stability
4,No moving parts, no pressure drop, no maintenance.
5,wide bi-directional flow range of 0 to ±40 ft/s (0 to ±12 m/s)
6,wide range of pipe sizes from 65mm to 4570mm.
7,Signal quality tracking and self-adjusting capabilities.
8, Enhanced extended transducers for cement pipeline, less than 100mm wall thickness permitted.
9, Up to 8GB SD card data logger optional, time interval can be freely setup by user.
10,Suited high temperature: -40°C~150°C.
Applications:
1,Water, including hot water, chilled water, city water, sea water etc.
2,Secondary sewage, waste treatment, etc.
3,Oil, including lubricating oil, diesel oil, fuel oil, etc.
4,Beverage, food and pharmaceutical processor
5,HVAC, energy measurement system, etc.
Specifications
Transmitter | Power Supply | (Std) 10-28 VDC @ 2.5VA max.115/230VAC 50/60Hz ±15%@ 5VA max. |
Velocity | 0~ ±40 ft/s (0 ~ ±12m/s), bi-directional | |
Display | 4 line×16 English letters LCD back lit, can display total flow, flow rate, velocity and meter running status etc. | |
Units Rate Totalized | User Configured (English and Metric); Rate and Velocity Display; (FWD, NET, REV or BATCH) gallons, ft³, barrels, lbs, liters, m³,kg | |
Output | 4~20mA, OCT Pulse, Relay, RS232C or RS485, options: up to 8 GB Data logger, Hart + (4~20mA), Modbus. | |
Accuracy | ±1.0% of reading at rates >0.5 m/s | |
±0.005m/s of reading at rates < 0.5 m/s | ||
Sensitivity | Flow Rate: 0.001ft/s (0.0003m/s) | |
Repeatability | 0.2% of reading | |
Security | Keypad lockout, access code enable | |
Dimensions and Weight | Std.:241*193*76.5 Weight: <2.5kg | |
Exp: 255*220*110 Weight: <5.0kg | ||
Transducer | Liquid Types Supported | Virtually most any liquid containing less than 2% total suspended solids (TSS) or aeration |
Pipe Range | 65mm-4570mm | |
Suited Liquid Temperature | Std. Temp. Transducer: -40°C~121°C High Temp. Transducer: -40°C~150°C | |
Cable Length | Shielded transducer cable. Standard length 20fts (6m). Can be extended to 990fts (300m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power line; neither should it be close to strong interference source such as power transformers. | |
Dimensions | Std.: φ20mm, 190mm; weight:<0.6kg Extended: φ20mm, 325mm; weight:<1.6kg |
Transmitter
Standard Transducer
Extended Transducer
Data Logger
CE Ceritifate