Home  >  Testing Equipment

IEC60884 Figure11,VDE0620,Clamping Device Test Machine - ZLT-DSG2

IEC60884 Figure11,VDE0620 - more info check here: http://www.buymeasuringtools.com/IEC60884-Figure11-VDE0620-Clamping-Device-Test-Machine-10002379/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: ZLTJC Model Number: ZLT-DSG2 Power: Electronic Usage: Universal Testing Machine material: stainless steel

Product Features:

IEC60884 Figure11,VDE0620

Business Terms:

Port: Guangzhou

Minimum Order Quantity: 1 Piece/Pieces negotiable

Supply Ability: 10 Piece/Pieces per Month negotiable

Payment Terms: T/T,Western Union,MoneyGram,cash

Contact Supplier
IEC60884 Figure11,VDE0620,Clamping Device Test Machine
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: wooden case

Delivery Detail: 3-100days

Specifications and Product Details:

Apparatus of checking damage to conductors:

Product details:Model ZLT-DSG2

Application:

Terminals with screw clamping shall be so designed and constructed that they clamp the conductor(s) without undue damage to the conductor(s).

Compliance is apparatus of checking damage .

The terminal is placed in the test apparatus according to tester and fitted with rigid, solid, stranded and/or flexible conductor(s), according to standard first with the smallest and then with the largest nominal cross-sectional area, the clamping screw(s) or nut(s) being tightened with the torque according to standard.

The length of the test conductor shall be 75 mm longer than the height (H) specified in standard.

The end of the conductor is passed through an appropriate bushing in a plate positioned at a height (H) below the equipment, as given in standard. The bushing is positioned in a horizontal plane such that its centre line describes a circle of 75 mm diameter, concentric with the centre of the clamping unit in the horizontal plane; the platen is then rotated at a rate of (10 ± 2) r/min.

The distance between the mouth of the clamping unit and the upper surface of the bushing shall be within ±15 mm of the height specified in standard. The bushing may be lubricated to prevent binding, twisting, or rotation of the insulated conductor.

A mass as specified in standard is suspended from the end of the conductor. The duration of the test is approximately 15 min.

During the test, the conductor shall neither slip out of the clamping unit nor break near the clamping unit, nor shall the conductor be damaged in such a way as to render it unfit for further use.

Power Supply220V 50Hz or 115V 60Hz
No.of Test1~9999
Rate of Testing(10±2)r/min
Weight300g/400g/700g/900g/1400g/2000g*1
Bushing37.5mm
Diameter of bushing hole (mm)6.5,9.5,13,14.5
Height(H)(mm)260,280,300,320
Conforms to standardIEC60884Figure11,VDE0620,IEC60947.1 Figure 1
IEC60884 Figure11,VDE0620,Clamping Device Test Machine suppliers    IEC60884 Figure11,VDE0620,Clamping Device Test Machine manufacturers